Tagsys S.A. MEDIOL40 User Manual

Page of 56
 
Medio L40 - User's Guide 
 
 
22/56 
Revision 2.3 
July 2013 
 
 
 
 
 
 
 
 
For USA and countries under FCC Part 15 regulation only use the Antenna and Power 
Supply Unit combination tested and specified in the cross reference table of the 
corresponding Medio L40 (see section
 2.2.2 FCC ID Cross Reference Table
). The use of 
any other combination of reader version, antenna type and Power Supply Unit is subject to 
obtaining a specific FCC ID either by TAGSYS or by its Qualified Partner under TAGSYS 
supervision. 
 
For other countries, only use Power Supply Units GS40A24-P1J or A2-50S18R-V or 
FRA045E-S24-4. If using any other Power Supply Unit , the selected Power Supply Unit 
must meet all following criteria:  
 
UL Listed UL60950 and CB Certified for Information Technology Equipment 
 
Class B Emission CISPR22 EN55022 
 
CE marked 
 
LPS 
4.3  Using USB Interface 
4.3.1  Installing USB Drivers 
At first connection to the PC USB port, Windows® will detect the TAGSYS Medio L40 reader and 
will ask to install a driver. The USB drivers are located into the USB Drivers folder on the product 
CD-ROM. 
Two drivers will be installed: 
-
 
The USB device driver. 
-
 
The virtual COM port (VCP) driver. The VCP driver emulates a standard PC COM port. 
After installation of the drivers, power up and connect your Medio L40 to a spare USB port on your 
PC to launch the Windows Found New hardware Wizard 
  Select “No, not this time” and click next to proceed with the installation. 
  Select “Install from a list or specific location (Advanced)” and then click “Next”. 
  Select “Search for the best driver in these locations” and click the Browse button to select 
the TAGSYS USB Drivers folder on the Product CR-Rom. Then click “Next” to proceed. 
  Windows should then display a message indicating that the installation was successful. 
Click Finish to complete the installation. 
Repeat the procedure above when Windows® asks for drivers again (virtual com port). 
In order to confirm that the installation has completed successfully, open the Device Manager and 
select “View > Devices by type”.  The TAGSYS Medio L40 reader now appears as an additional 
COM port.  
 
4.3.2  Using the USB interface 
Once the USB drivers are properly installed, the reader appears as a new COM port. Simply 
connect to this COM port at 115200 Bauds to access the reader.  
 
Drivers  for Windows  98  are  not  provided.  They  are  available  upon  request  (please  contact 
TAGSYS).