3.  In the “Single Block Operations” box, select the block and data you  want to write (data is 
hexadecimal). You can pad bytes with whitespaces if you wish, but this is not required. 
 
Figure 14: Single Block Operations 
 
 
 
The length in bytes of a single block depends on the tag manufacturer, but most ISO 15693 
tags use four bytes blocks. See TAGSYS Explorer User’s Guide for more information. 
 
4.  Place a single ISO15693 tag in the radio field of the channel 1 antenna. 
5.  Click “Write” to write data to the block. If writing is successful, no error message appears. 
To  check  block  data,  clear  the  “Data”  field  and  click  “Read”  to  read  data  back  from  the 
block. 
4.7.5  Upgrading System or Radio Firmware 
If you have not configured your device using TAGSYS Explorer wizard as explained in section
 
4.7.2
 
Connecting to a device using Tagsys Explorer Wizard
, please do so before proceeding. 
Two different firmware sets can be upgraded in your RFID reader: 
  System  firmware  (The  system  is  in  charge  of  interfacing  one  or  several  radios  to  a  host 
through various interfaces and protocols) 
  Radio firmware (The radio is in charge off all RFID operations).