5.3.1  Notion of read modes 
During asynchronous read (or default read), the reader continuously tries to read all tags in the RF 
field. Several options can be applied that modify the reader’s behavior during asynchronous read: 
  “Multiplexer”:  If  this  mode  is  active,  the  reader  uses  the  multiplexer  instead  of  the  default 
RF  configuration  for  reading.  The  multiplexer  makes  it  possible  to  define  a  sequence  of 
antennas,  tag  types  and  RF  output  powers  that  will  be  automatically  used  during  the 
reading process. For example, a user can configure the multiplexer so that reader tries to 
read  ISO15693  tags for 100ms  on  channel  1  at 1Watt, then  ICode  UID  tags for  50ms  on 
channel 1 at 2Watts, then ISO15693 tags for 100ms on channel 2 at 1Watt, then ICode UID 
tags for 50ms on channel 2 at 2Watts.  
  “Input triggered”: If this mode is active, the reader waits for GPIO Input #1 to become active 
in  order  to  activate  the  RF  field  and  start  reading.  When  GPIO  Input  #1  gets  back  to 
inactive state, RF field is turned off and the reader stops reading until input is active again. 
Active input level (low or high) is software configurable. 
  “Output  feedback”:  If  this  mode  is  active,  the  reader  uses  GPIO  Outputs  #2  to  signal 
reading activity. GPIO Output #2 is activated when the reader “sees” tags in the RF field. 
The time an output remains active after the corresponding event has occurred is software 
configurable. 
  “Single”: If this mode is active, the reader will only scan once the current RF configuration. 
Not applicable in non-multiplexer mode with C210 and C220 tags. 
 
A user can activate one or several read modes at once, depending on the application 
requirements. 
 
5.3.2  Notion of events 
During asynchronous read (or default read), the reader continuously tries to read all tags in the RF 
field. When a tag is detected, one or several events are pushed into an internal event buffer. Those 
events  contain  information  such  as  the  kind  of  event  (see  below),  a  timestamp,  the  channel  on 
which the event occurred, the tag type and the associated tag data (UID, memory…). The following 
events are supported: 
 
  “Tag Read”: This event is pushed each time a valid tag frame is decoded, without further 
processing.  When  activated,  this  event  may  be  triggered  several  hundreds  of  times  per 
second and is consequently bandwidth consuming. It is often used for testing purpose only. 
  “Tag  New”:  This  event  is  pushed  each  time  a  new  tag  is  detected.  If  the  same  tag  is 
detected several times, it will be reported only once. 
  “Tag In”: This event is pushed each time a tag enters the RF field. 
  “Tag Out”: This event is pushed each time a tag leaves the RF field.  
  “Tag No Read”: When Input triggered read mode is active, this event is pushed when the 
trigger condition ends and no tag was detected in the RF field. When Input triggered read 
mode is inactive, this event is never pushed. 
 
A user can register for one or several events at once, depending on the application requirements. 
 
For example, if a user registers for all events and a tag enters the RF field, stays in the field for 
some time, and then leaves the field, the sequence of events pushed into the event buffer will be: