Zebra 77236 User Manual

Page of 234
112
Z4Mplus and Z6Mplus Maintenance Manual
13358L Rev. 1 11/17/03
Section 4
Preventive and Corrective Maintenance
5.
Refer to Figure 4-48. Using a 0.060 in. (1.5 mm) feeler gauge, check the distance 
between the ribbon/head open sensor assembly and the print mechanism assembly 
when closed. Once this distance is achieved, tighten the mounting screw.
6.
Refer to Figure 4-45. Close the media door and reinstall the electronics cover by 
aligning it and sliding down, ensuring the lower flange is inside the base and the 
upper flange is between the main frame and the media door.
7.
Refer to Figure 4-44. Reopen the media door and reinstall the mounting screw and 
lock washer to secure the electronics cover.
8.
Reinstall the media and ribbon.
9.
Reconnect the AC Power cord and data cables.
10.
Turn On (
l
) the printer and unlatch the print mechanism. Look at the front panel to 
ensure the error LED flashes. Close and latch the print mechanism.
11.
Turn Off (
O
) the printer. Press and hold CANCEL while turning On (
l
) the printer.
12.
A configuration label will print. Verify the sensor and printer work properly.
Figure 4-48.   Ribbon/Printhead Sensor Gap
0.060 in. (1.5 mm)
0.015
(0.381 mm)
±
in.
Ribbon/Printhead
Open Sensor
Mounting Screw
Print Mechanism