Replace Transmissive Sensor
Caution:
Caution • This installation must be performed by a qualified service technician.
Caution • This installation must be performed by a qualified service technician.
Caution • Turn Off (O) the printer and disconnect the printer from the power 
source before performing the following maintenance.
Remove Transmissive Sensor
1.
Turn Off (
O
) the printer and remove the AC power cord and data cables.
2.
Refer to Figure 4-49. Open the media door, remove the electronics cover mounting 
screw and lock washer.
3.
Remove the media and ribbon.
4.
Close the media door. 
Figure 4-49.   Locate Electronics Cover Mounting Screw
Note • 
The standard transmissive sensor is shown. The procedure is the same 
for the adjustable sensor.
Electronics
Cover
Media
Door
Electronics
Cover
Mounting
Screw
Lock Washer
Lower
Flange
Upper
Flange