Z4Mplus and Z6Mplus Maintenance Manual
113
Preventive and Corrective Maintenance
Section 4
Replace Transmissive Sensor
Caution:
Caution • This installation must be performed by a qualified service technician.
Caution • This installation must be performed by a qualified service technician.
Caution • Turn Off (O) the printer and disconnect the printer from the power
source before performing the following maintenance.
source before performing the following maintenance.
Remove Transmissive Sensor
1.
Turn Off (
O
) the printer and remove the AC power cord and data cables.
2.
Refer to Figure 4-49. Open the media door, remove the electronics cover mounting
screw and lock washer.
screw and lock washer.
3.
Remove the media and ribbon.
4.
Close the media door.
Figure 4-49. Locate Electronics Cover Mounting Screw
Note •
The standard transmissive sensor is shown. The procedure is the same
for the adjustable sensor.
Electronics
Cover
Media
Door
Electronics
Cover
Mounting
Screw
Cover
Mounting
Screw
Lock Washer
Lower
Flange
Flange
Upper
Flange
Flange