5. FOX3-KMD APPLICATION INTERFACE
5.1. Power supply
The power supply for the FOX3-KMD devices has to be a single voltage source of V
+IN 
+10.8 V...+32.0 V DC. The
operating voltage (V
+IN
) has to be applied permanently to the FOX3-KMD devices and able to provide sufficient
current of up to 1.5 A (pulse).
The operating voltage (V
+IN  
and GND) is not protected  against voltage spikes and reverse polarity, but  NOT
protected against continuous overvoltage.
NOTE:  Operating voltage range must never be exceeded; care must be taken in order to fulfill min/max
voltage requirements.
Signal name 
I/O 
Parameter
Description
+IN
I
+10.8 V...+32.0 VDC.
Positive operating voltage. 
GND
-
0 V
Ground (should be isolated from the vehicle grounds)
5.1.1. Automatic shutdown
Automatic shutdown takes effect if:
 under voltage is detected and internal battery level runs below the nominal voltage.
5.2. Determining the External Equipment Type
Before you connect the serial port pins of the FOX3-KMD devices to an external equipment, you need to
determine if the external hardware serial ports are configured as DTE (Data Terminal Equipment) or DCE (Data
Communications Equipment)
.
FOX3-KMD   is   designed   for   use   as   DCE   devices.   Based   on   the  conventions   for   DCE-DTE   connections,   it
communicates with the customer application (DTE) using the following signals:
FOX3-KMD Terminal (DCE)
to
Application (DTE)
RxA
<----------
TXD
TxA
---------->
RXD
GND
-
GND
Table 3: The signaling definitions between DTE and DCE.