6.1. Main Port (8pin connector)
    
Figure 2:
Pin assignments of 8-pin (2x4) connector 
and installation cable connection (CA39 with 2A fuse).
6.1.1. Main Port Pinout
PIN
NAME
DIRECTION
DESCRIPTION
LEVEL
1
+IN
Input
Power   supply   input.   The   power   supply   must   be
able   to   meet   the   requirements   of   current
consumption.  For   security   reason,   it   is
recommended to integrate externally a 2A fuse link
between power source and FOX3-KMD.
V
+IN
 = + 10.8 ... + 32.0 V 
Imax ≤ 1.5 A
2
GND
-
Ground.
0 V
3
IGN
Input
General purpose input. It can be either connected
to   the   vehicle   ignition   and   be   used   for   journey
START and STOP reports, or be connected to the
operating voltage +IN and be used to wakeup the
FOX3-KMD devices from IGN-Sleep mode (awaking
from this mode requires a HIGH signal)
HIGH ≥+10.8 .. +32.0 V DC; LOW = 0V
4
I/O1
Output
Open collector digital output
OUT: 100 mA max. @ +0 .. +32.0V DC
5
I/O2
CAN-LOW
6
I/O3
CAN-HIGH
7
RxA_0
Input
(Serial   Port   0)  The   serial   port   (receive   data)  for
direct connection to the host PC (for configuration,
evaluation, firmware). If this pin is not used leave it
open.
8
TxA_0
Output
(Serial Port 0) Serial port (transmit data) for direct
connection to the host PC (for transmitting history
data, output GPS protocols and more). If not used
leave it  open.
V24, ±12 V
Table 5: Description of the main port (8-pin connector)
6.1.1.1.
Serial Port 0 - Serial communication signals (RxA and TxA)
FOX3-KMD devices incorporates a full duplex serial channel which allows two devices to communicate directly
with each other via the RS232 serial port.
RxA_0
Main   channel   used   to   receive   software   commands   to   the   board   from   any
software (e.g. HyperTerminal). Moreover, the firmware update can also be done
through this serial port.
TxA_0
Main channel used to output navigation, measurement, response and system
data to any software (e.g. HyperTerminal, FALCOM Workbench).
This confidential document is a property of FALCOM GmbH and may not be copied or circulated without previous permission.
Page 15 of 23