TroublesHooTinG Guide
problem
Causes
solutions
Controller.shows.“ERR”.in.display
.Module.wires.not.properly.
connected.to.controller.terminal
Check.the.connection.between.module.and.controller.and.compare.to.
wiring.diagram.in.System.Installation.section.of.Owner’s.Manual
Solar.Sync.module.shows.“ERR”
.Connection.between.module.and.
sensor.faulty
Check.connection.between.module.and.sensor.(green.and.black.wires)
Seasonal.Adjust.seems.low
.Region.too.high
.Water.Adjustment.Setting.too.low
.Location.of.Sensor.does.not.allow.
for.full.sun
Make.sure.controller.dial.is.in.“RUN”.position..Increase.the.value.on.
the.Water.Adjustment.scale.(the.default.setting.is.5)..If.you.max.out..
the.Water.Adjustment.scale.at.10.and.still.require.more.seasonal..
adjustment,.move.down.one.Region.(from.4.to.3,.for.example).and.start.
at.Water.Adjustment.setting.5..Solar.Sync.will.immediately.update.the.
Seasonal.Adjust.on.the.controller..If.it.is.still.too.low,.repeat.the.adjust-
ment.until.the.desired.seasonal.adjust.is.showing.on.the.controller..
Seasonal.Adjust.seems.high
.Region.too.low
.Water.Adjustment.setting.too.high
Make.sure.controller.dial.is.in.“RUN”.position..Decrease.value.of.the.
Water.Adjustment.setting..If.you.minimize.the.Water.Adjustment.scale.
at.1.and.still.require.a.reduced.seasonal.adjustment,.move.down.up.
one.Region.(from.2.to.3,.for.example).and.start.at.Water.Adjustment.
setting.5..Solar.Sync.will.immediately.update.the.Seasonal.Adjust.
on.the.controller..If.it.is.still.too.high,.repeat.the.adjustment.until.the.
desired.seasonal.adjust.is.showing.on.the.controller..
Rain.or.Freeze.shutoff.not.activating
.Rain.Sensor.Bypass.Switch.on.
Controller.set.to.“Bypass”
.Jumper.Clip.still.on.controller.
wiring.terminal
Set.the.Controller.Bypass.Switch.in.the.“Active”.position.
Remove.jumper.clip.
Run.times.for.a.particular.station.are.
too.short/too.long
.Program.Run.Time.too.long/
too.short
Solar.Sync.provides.a.global.seasonal.adjustment.to.the.controller...
If.a.particular.station.has.run.times.too.long.or.too.short,.make.the..
appropriate.adjustment.to.the.program.in.the.controller..
Solar.Sync.still.sending.Seasonal..
Adjust.when.Controller.Bypass.
switch.in.the.“Bypass”.position
.Solar.Sync’s.automated.seasonal.
adjustment.cannot.be.de-activated.
by.the.Bypass.switch.
.The.Bypass.switch.only.controls.the.
Rain/Freeze.shutoff.function.of.the.
Solar.Sync
Hunter Technical Service:.1-800-733-2823.or.www.hunterindustries.com/Support/Ask_Expert/default.htm