Cross Point b.v. CP301MAXRXA User Manual

Page of 72
Technical Manual AM Systems 
 
 
 
 
 
Connections 
v4.4 
Page 31 of 72 
6.10.3 
I/O connections 
The  AM  TRX  board  is  equipped 
with  two  I/O’s  which  can  be  used  for  connecting  a 
pushbutton (Forced Alarm option) or as output for other external devices (e.g. camera). 
To avoid interference, caused by the wires which will be connected to any of the I/O’s, it 
is very important to only connect the wires to the I/O connector contacts. 
Do not connect any of the wires directly to a GND contact on the TRX board or on 
the power supply! Use the “GND” connector to connect to the ground. 
The I/Os have a current limit of 70mA. Do not connect devices to the I/Os that draw more 
than 70mA, else the I/O drivers will get damaged! 
shows the proper way to connect a “Forced Alarm” pushbutton between “I/O1” 
and “+”. 
 
 
Figure 16: Proper I/O connections 
I/O2 
I/O1 
GND 
FTP 
TRX board