6.10.3
I/O connections
The AM TRX board is equipped
with two I/O’s which can be used for connecting a
pushbutton (Forced Alarm option) or as output for other external devices (e.g. camera).
To avoid interference, caused by the wires which will be connected to any of the I/O’s, it
is very important to only connect the wires to the I/O connector contacts.
is very important to only connect the wires to the I/O connector contacts.
Do not connect any of the wires directly to a GND contact on the TRX board or on
the power supply! Use the “GND” connector to connect to the ground.
the power supply! Use the “GND” connector to connect to the ground.
The I/Os have a current limit of 70mA. Do not connect devices to the I/Os that draw more
than 70mA, else the I/O drivers will get damaged!
than 70mA, else the I/O drivers will get damaged!
shows the proper way to connect a “Forced Alarm” pushbutton between “I/O1”
and “+”.
Figure 16: Proper I/O connections
+
I/O2
I/O1
GND
FTP
TRX board