The visitor counter 
The  AM  models  can  be  equipped  with  a  visitor  counter.  This  counter  allows  counting  of 
visitors  as  well  as  determining  the  movement  direction  of  a  person  who  generated  an 
alarm. 
Both  TRX  and  RX  antennas  can  therefore  be  equipped  with  a  visitor  counter  PCB.  The 
TRX antenna holds the RX visitor counter PCB (IR-RX) and the RX antenna holds the TX 
visitor counter PCB (IR-TX). 
Figure 18 shows the visitor counter principle. 
 
 
Figure 18: Top view of the visitor counter principle 
 
The IR LED on side B of the RX antenna transmits an infra-red signal, which is received 
by both IR receivers on side A of the TRX. When the infra-red signal is interrupted by a 
person  walking  in  (incoming),  first  IR-RX1  will  receive  no  signal  and  then  IR-RX2  will 
receive  no  signal.  In  this  way  the  visitor  counter  registers  the  movement  direction.  The 
same principle is used for outgoing persons. 
As  shown  in  the  above  figure,  each  visitor  counter  PCB  has  an  A  and  B  side.  The 
transmitter  IR-
LED’s  and  the  IR  receivers  can  be  switched  on  or  off  per  side.  This  is 
necessary  for  each  first  and  last  antenna  in  a  row.  For  example,  if  the  system  in  the 
above  figure  consists  just  of  two  antennas,  then  the  visitor  counter  side  B  of  the 
transceiver antenna and side A of the receiver antenna must be switched off. The Device 
Explorer software will automatically activate the visitor counters dependent of the antenna 
lay-out. 
It  is  possible  to  increase  the  intensity  of  the  IR-
LED’s.  This  can  be  useful  in  bright  and 
sunny environments, to ensure proper functioning of the visitor counter.  
For the visitor counter to operate properly the minimum distance between the transceiver 
and receiver is 0.5m. The maximum distance is 3m (per aisle). 
visitor counter PCB (IR-TX) 
visitor counter PCB (IR-RX) 
IR LED’s 
IR Receivers 
Side B 
Side B 
Side A 
Side A 
In
c
o
m
ing
 
IR-RX1 
IR-RX2 
Ou
tg
o
ing