3. DC Output Specification 
3.1 Output Current / Loading 
The following tables define two power and current rating. The power supply shall meet both static and 
dynamic voltage regulation requirements for minimum load condition. 
 
Single rail for +12V 
Output 
Voltage 
+5V 
+3.3V 
+12V (Single Rail) 
-12V 
+5VSB
Max. Load 
30A 
28A 
60A 
0.5A 
4A 
Min. Load 
1.0A 
0A 
3A 
0A 
0.1A 
Max. Combined 
180W 60A 
 
 
Total Output 
730W 6W 
15W 
Table 5 – Output Loads Range 1: 
Note 1: Maximum continuous total DC output power should not exceed 750 W. 
 
3.2 DC Voltage Regulation, Ripple and Noise 
The power supply output voltages must stay within the following voltage limits when operating at 
steady state and dynamic loading conditions. All outputs are measured with reference to the return 
remote sense (ReturnS) signal. The +5V,+3.3V, +12V, -12V and +5VSB outputs are measure at the 
power supply connectors references to ReturnS. The +5V and +3.3V is measured at its remote sense 
signal (+5VS, +3.3VS) located at the signal connector.   
Output Voltage 
+5V 
+3.3V
+12V
-12V  +5VSB 
Load Reg. 
+/-3%
+/-3%
+/-3%
+/-10% +/-5% 
Line 
Reg. 
±1% ±1% ±1% ±1% ±1% 
Ripple & Noise   
50mV
50mV 120mV 120mV 50mV 
Table 7 – Regulation, ripple and noise 
 
Ripple and Noise shall be measured using the following methods: 
a) Measurements made differentially to eliminate common-mode noise 
b) Ground lead length of oscilloscope probe shall be 
≤ 0.25 inch. 
c) Measurements made where the cable connectors attach to the load. 
d) Outputs bypassed at the point of measurement with a parallel combination of 
10uF tantalum capacitor in parallel with a 0.1uF ceramic capacitors. 
e) Oscilloscope bandwidth of 0 Hz to 20MHz. 
f) Measurements measured at locations where remote sense wires are connected. 
g) Regulation tolerance shall include temperature change, warm up drift and dynamic load 
3.3 Timing Requirements   
These are the timing requirements for the power assembly operation. The output voltages must rise 
from 10% to within regulation limits (T
vout_rise
) within 5 to 70mS. The +5V, +3.3V and +12V output