Trisquare Communications Inc. WBASE User Manual

Page of 7
1.  If the inserted MIC is the only MIC currently synced to that BASE, the MIC shall stop 
transmitting audio and shall transmit a data packet with the security code and the turn off 
command to the BASE unit to stop recording. 
2.  If the inserted MIC is one of two MICs currently synced to that BASE and it is in an active 
record session, the MIC shall stop transmitting audio and shall transmit a data packet with 
the security code and the turn off command to the BASE unit to stop recording.  The BASE 
shall stop the record session with that MIC, but not the other MIC if it is also active. 
3.  If the inserted MIC is not one that is currently synced to that BASE, sync with that MIC shall 
be held off until the record session is ended either by manually turning off the record 
session or by inserting the one or both active MICs into the BASE. 
 
 
 
 
General Specifications: 
 
Operating Frequency Range 
902 – 928 MHz 
Operating Voltage 
9 to 15 VDC 
Frequency Hopping Sequences 
32,768 
Frequencies per Sequence 
16 
Audio Output 
250 mV RMS 
Range 
1000 ft 
 
 
FCC Information: 
 
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS 
SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MAY NOT 
CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY 
INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE 
UNDESIRED OPERATION. 
 
An FCC license is not required for operation of this device.  
 
The ICOP Digital 20/20-WBASE must be installed by a qualified professional using one of 
the two antennas supplied with the product: 
 
Rubber Duck Antenna 
ICOP PN 600-00143 
Roof Mount Antenna 
ICOP PN 600-00142 
 
Unauthorized modifications to this equipment could void the user’s authority to operate this 
equipment.