Supplying Power to the NetVanta 150 Unit
The NetVanta 150 unit can be powered either by the LAN Ethernet connection or through the 12 VDC 
external supply. The Wall Supply is not included in shipment of this unit but can be requested from Adtran 
or your reseller. See Product Support Information on page 9 for more information on contacting Adtran.
Connect to the NetVanta 150 Unit
1. Connect the NetVanta 150 unit to the PC using the 
ETH
 port on the back of the unit and  the 
appropriate Ethernet cable.
2. Supply power to the PC and the NetVanta 150 unit and begin the operating system boot up process. 
During boot up, the PC will obtain an IP address from the NetVanta 150 unit DHCP server. By 
default, both the DHCP and HTTP servers are enabled. The default IP address is 10.10.10.1.
3. Enter the unit’s IP address in your browser address line. The default IP address is 
10.10.10.1
.
4. You will then be prompted for the username and password (the default settings are 
admin
 and 
password
).
5. The initial GUI screen appears.
6. Click on 
Getting Started
 in the 
System
 menu on the left side of your screen and follow the 
on-line instructions.
Factory Default Switch
If the factory default switch is pressed during bootup, the unit will stay in bootstrap mode. Since the unit 
has no serial port, Telnet has been built into the boot code. The default IP address is 10.10.10.1.
If the factory default switch is pressed and held for 5 seconds after boot, the 
ETH
 interface on the 
NetVanta 150 will default to 10.10.10.1 and all access policies will be removed from that interface.
If the factory default switch is pressed for 30 seconds, a default configuration will overwrite your 
existing configuration and reboot the unit.
The 10/100BaseT Ethernet interface MUST NOT be metallically connected to interfaces 
which connect to the Outside Plant or its wiring. This interface is designed for use as an 
intrabuilding interface only. The addition of primary protectors is not sufficient protection 
to connect this interface metallically to OSP wiring.
For security purposes, you should set up an admin password immediately. Use the 
Passwords page of the Web GUI to change this password.
The default switch must be pressed WHILE the  power light is flashing green. Do not press 
the default switch BEFORE the power light is flashing green, as this will cause boot to be 
missed.