>DS3 S
TATUS
/C
ONFIGURATION
/L
OOPBACK
 > DS3 L
INE
 B
UILD
 O
UT
Configures the DS3 for the appropriate line buildout, based on the distance to the DS3 equipment. Use 
DSX
 for 0-255 feet and 
H
IGH
 for distances greater than 255 feet.
>DS3 S
TATUS
/C
ONFIGURATION
/L
OOPBACK
 > A
LARM
 R
EPORTING
Determines whether the TRACER 4305 unit will report active alarms. If 
D
ISABLED
, no alarms will be 
displayed on this menu page. The 
A
LARM
 R
EPORTING
 parameter is independently configured for the local 
and remote TRACER 4305 units. 
>DS3 S
TATUS
/C
ONFIGURATION
/L
OOPBACK
 > S
IGNALING
Configures the framing format for the DS3 link for both the local and remote TRACER 4305 units. The 
TRACER 4305 transparently transports DS3 data across the link (as long as the DS3 signal is properly 
timed). Configure the framing format (using the 
S
IGNALING
 menu) to enable the TRACER 4305 to monitor 
incoming framing error events and indicate problems with the attached metallic service. The TRACER 
4305 supports both 
M13
 and 
C-B
IT
 parity modes.
>DS3 S
TATUS
/C
ONFIGURATION
/L
OOPBACK
 > L
INE
 C
ODE
Sets the line coding for the DS3 link. The TRACER 4305 supports only 
B3ZS
 line coding.
>DS3 S
TATUS
/C
ONFIGURATION
/L
OOPBACK
 > L
OOP
/N
ORMAL
 S
TATE
Controls the loop status of the DS3 link. Activates/deactivates loopback conditions for testing purposes.
>DS3 S
TATUS
/C
ONFIGURATION
/L
OOPBACK
 > L
OOP
/N
ORMAL
 S
TATE
 > N
ORMAL
The DS3 link is in normal data transport mode - there are no active loopbacks.
>DS3 S
TATUS
/C
ONFIGURATION
/L
OOPBACK
 > L
OOP
/N
ORMAL
 S
TATE
 > L
INK
Activates a loopback at the TRACER 4305 DS3 framer towards the wireless link (see Figure 7). Use the 
L
INK
 loopback to test data path integrity from one unit across the wireless link.
Figure 7.  DS3 Link Loopback
LOS
Activates when no DS3 signal is present from the connected DS3 equipment. LOS is 
activated after receiving 192 consecutive zeros.
LOF
Activates when the DS3 framer loses alignment due to too many F bits or M bits in error.
IDLE
Connected DS3 equipment is indicating that the line is not in use by transmitting a 
properly aligned and frame 1100... pattern.