Senstar Corporation LM100 User Manual

Page of 74
Senstar LM100 Product Guide
Page 19
2
Installation
Installing LM100 luminaires
Generally, a luminaire is attached to every second fence post (6 m spacing). In addition, all of the 
heavier gauge fence posts should have a luminaire (tension posts, corner posts, gate support 
posts). The luminaires should be installed on the side of the fence that faces the perceived threat. 
Luminaires are installed so they are perpendicular to the fence line and plumb, with the head 
facing directly downward.
The first step is mounting the gateway (or indicate the gateway’s installation location if it will be 
installed later). Begin with the luminaire AP (the luminaire with a hard-wired connection to the 
gateway).
At regular fence posts
Tools and equipment
8 mm (5/16 in.) nut driver or socket (low torque cordless drill with 8 mm socket recommended)
ladder or scissor lift suitable for fence height
Figure 9: Senstar LM100 concept drawing
Tip
Using a quick-grip clamp will simplify the installation of the luminaires.
2.4 GHz wireless mesh network (encrypted and supervised)
luminaire AP
luminaire
gateway
48 VDC network
RS-485 connection
low voltage power
to luminaires
typical luminaire spacing
6 m (20 ft.)
cable connection
(up to 100)
(1 required)
discrete inputs (light control)
discrete outputs (alarms / control points)
network interface to SMS
power supply for
gateway and luminaires
 between gateway
 and luminaire AP