Senstar Corporation LM100 User Manual

Page of 74
Installing LM100 luminaires
Senstar LM100 Product Guide
Page 25
Tools and equipment
crimp tool (see 
wire stripper
wire cutter
linesman’s pliers
needle-nose pliers
ruler
ladder or scissor lift suitable for fence height
For daisy chain power cable wiring attach the power cable along the top of the fence:
1. Run the 2 sections of power cable from the top of the fence, down past the luminaire, and cut 
the power cables 30 cm (1 ft.) below the base of the luminaire.
2. Separate the 2 conductors of the power cables for 10 cm (4 in) from the end.
CAUTION
Use power cable that clearly distinguishes the 2 conductors to ensure 
the correct polarity at each luminaire.
CAUTION
Once the supplied grommet is inserted into the base of the luminaire it 
is virtually impossible to remove without damaging the grommet. 
Temporarily apply power and test each luminaire before inserting the 
grommet.
Note
Molex crimp tool p/n 64001-0600 is recommended for use with the 
supplied Molex crimp connectors. However, the Klein model 1005 or 
equivalent crimp tool is suitable for this application.
Note
In harsh weather environments which include wind blown salt water 
spray, Senstar recommends the use of a protective marine type 
dielectric grease compound for the electrical connection to the 
luminaires.
Figure 20: Power connection crimp tools
Figure 21: Power cable preparation
Molex SD-19160-001
closed-end connector
Molex 64001-0600 recommended crimp tool
Klein 1005 suitable crimp tool
10 cm (4 in.) 1 : 1 scale
3 cm (1.2 in.) 1 : 1 scale