Scheduling routine light activation
Senstar LM100 Product Guide
Page 61
Scheduling routine light activation
Once the segment and zone assignments are made, a schedule can be setup for routine light 
activation. The Senstar LM100 enables up to 8 independently scheduled light activations for 
defined luminaire zones. Set the light level (brightness) for normal light control on the Config tab. 
Specify the time at which the lights turn on, the time at which the lights turn off, the days of the 
week on which the activations occur, and the zone to which the schedule applies, on the Schedule 
tab. 
Scheduling routine luminaire activation
1. On the Config tab, use the slider in the Normal Light Control section to set the brightness of 
the luminaires that will be activated by the schedule.
2. Select the Schedule tab and select (check) the first scheduling checkbox.
3. Set the time at which the luminaire(s) will turn ON.
4. Set the time at which the luminaire(s) will turn OFF.
5. Choose the days of the week that the activation will occur.
6. Choose the luminaire zone that will activate according to the schedule.
7. Save the UCM file and download the configuration changes to the LM100 gateway.
Figure 55: Setting individual segment Thresholds
select a checkbox to setup a
set the time at which the lights
routine lighting schedule
 turn On and Off
select the days of the week
specify the zone to activate
(select All to activate all
 installed luminaires)