Chapter 3:  Electrical and Environmental Specifications
 December 15, 2009
G30 - Module Hardware Description
61
Environmental Specifications
 gives the environmental operating conditions of the G30 module.
Caution:
Exceeding the values may result in permanent damage to the module.
Application Interface Specifications
 summarizes the DC electrical specifications of the application interface connector 
signals.
Important:
Interface signals that are not used by the customer application must be left 
unconnected. G30 incorporates the necessary internal circuitry to keep unconnected 
signal in their default state. Do not connect any components to, or apply any voltage 
on, signals that are not used by the application.
Important:
Signals that are defined as "Do Not Use", or DNU, must remain externally 
unconnected in any case. These signals are reserved for future use.
 give a brief description of the 70 pins connector and the 81 pin LGA 
interface irrespectively for quick integration.
Table 3-12: Environmental Ratings
Parameter
Conditions
Min
Max
Unit
Ambient Operating 
Temperature
-30
85
°C
Storage Temperature
-40
85
°C
ESD
At antenna connector
                    Contact
                    Air
At interface pads/con-
nector
± 8
± 15
± 1
KV