Radio Frequency Interference Requirements
The Harmony 802.11a Access Point Models 8569 and 8570 operate in the frequency 
range of 5.15 to 5.35 GHz; they are restricted to indoor use due to their operation in the 
5.15 to 5.25 GHz frequency range.  FCC 15.407(e) requires that these devices be used 
indoors in the frequency range of 5.15 to 5.25 GHz to reduce the potential for harmful 
interference to co-channel Mobile Satellite systems.  Therefore the devices should be 
used indoor only for channels 36, 40, 44 and 48 and when 2X mode is enabled, 
channels 42 and 50.  The Harmony 802.11a Access Point Model 8571 operates in the 
frequency range of 5.25 to 5.35 GHz and is not subject to the above restriction.
Note:
High power radars are allocated as primary users of the 5.25 to 5.35 GHz and 
5.65 to 5.85 GHz band.  These radar stations can cause interference with 
and/or damage the Harmony 802.11a Access Point (Models 8569, 8570, and 
8571).
Industry Canada Guidelines
Models 8569 and 8570 have been designed to operate with antennas having a 
maximum gain of 6 dBi.  Model 8571 has been designed to operate with an antenna 
having a maximum gain of 12 dBi.  Antennas having higher gains are strictly 
prohibited per regulations of Industry Canada.  The required antenna impedance is 
50 ohms.  To reduce potential radio interference to other users, the antenna type and 
its gain should be so chosen that the equivalent isotropically radiated power (EIRP) is 
not more than that required for successful communication.  The installer of this radio 
equipment must ensure that the antennas are located or pointed such that they do 
not emit RF field in excess of Health Canada limits for the general population; consult 
Safety Code 6, obtainable from Health Canada’s website 
http://www.hc-sc.gc.ca/rpb.