KAPSCH TRAFFICCOM CANADA INC. 802295 User Manual
_
JANUS
®
Multi-Protocol Reader Ver. 2: Maintenance Instructions
Confidential
UM
360450-210: A7
Page 194 of 282
© Kapsch TrafficCom Canada Inc. 2013
These drawings and specifications contain confidential and proprietary information and are the property of Kapsch TrafficCom Canada Inc. and are issued in strict
confidence and will be kept confidential and used solely for the purpose intended and for no other purpose and shall not be transmitted, reproduced, copied, and/or
used as the basis for manufacture or sale of apparatus unless otherwise agreed to in writing by Kapsch TrafficCom Canada Inc.
FILE: UM 360450-210 OPERATIONS AND MAINTENANCE MANUAL.DOCX
10/31/2013 7:56
Kapsch TrafficCom
Identifying failures on the primary and/or secondary side
Primary and/or Secondary side failure is indicated by any of the following conditions:
Ethernet LC link down, as indicated on the Reader browser Status page.
Ethernet IR network link down, as indicated on the Reader browser Status page.
Primary CTM MC or CGC
LED
s are red
Serial LC link down, as indicated on the Reader browser STATUS page
Primary side failure is indicated by any of the following conditions
SPM switch is in PRIMARY position: primary CTM ACTIVE
LED
is red
SPM switch is in AUTO position: primary CTM ACTIVE
LED
is red
Secondary side failure is indicated by any of the following conditions:
SPM switch in any position: secondary MC or CGC
LED
s are red
SPM switch is in SECONDARY position: secondary CTM ACTIVE
LED
is red
SPM switch is in AUTO position: primary CTM ACTIVE
LED
is red and secondary CTM ACTIVE
LED
is red.
Events that cause an automatic switchover
Table 6-4 outlines the situations that can cause an automatic switchover and what settings need to be
configured for the trigger to be enabled.
Table 6-4: Switchover triggers
Event
Cause
Enabling
Failed CGC Health
The Reader continuously monitors the CGC
health and forces a switchover if health fails.
Automatic
Failed Serial Lane
Controller Link
The Reader forces a switchover when an
enabled serial link from the LPM to the LC
has been interrupted. Usually a downed link
is due to external conditions.
Only the lack of OBU transactions in outgoing
Only the lack of OBU transactions in outgoing
messages to the LC allows a downed link to
be detected. To detect serial cable issues in
the absence of OBU transactions, the
operator must enable Heartbeat messages
Must enable Switchover on
Serial Link Down from
General tab on
Configuration page
Must set LC Retry Timeout
Must set LC Retry Timeout
from
Serial tab on
Configuration page
Set Heartbeat messages from
Set Heartbeat messages from
LC tab on Configuration
page