CAUTION: 
To avoid damaging the modules, ensure that the connector on the 
module properly aligns with the connector on the DSM back plane 
before the module is securely plugged into the DSM.
 
1.  Install a new PSM in the Reader Rack. 
2.  Set the power switch of the new PSM to the on position. 
3.  )Ensure that the new PSM +5 and +15 LEDs illuminate solid green. 
4.  Switch the Reader back over to the new PSM side (see Manually switching a Reader to the redundant side, 
page 39). 
 
CFM replacement 
WARNING: 
 
THE MODULES MAY HAVE SHARP EDGES. HANDLE THE MODULES 
CAREFULLY. WHENEVER POSSIBLE, USE A MODULE EXTRACTION 
TOOL TO REMOVE A MODULE. 
 
Removing a CFM  
1.  If possible, save the configuration file of the CFM being replaced (see Saving the Reader configuration, page 
2.  Remove the CTM on the side of the faulty CFM (see CTM, page 218).  
3.  While pushing on plastic clips, pull CFM straight out from DSM. 
Installing a CFM  
1.  Push CFM straight into connector on DSM until an audible click is heard. 
2.  Install the CTM removed in step 2 (see CTM, page 218). 
3.  Load the configuration file saved in step 1 to the new CFM (see Uploading a saved configuration, page 239)
or locate and upload the latest saved Reader configuration.