KAPSCH TRAFFICCOM CANADA INC. 802295 User Manual

Page of 282
JANUS
®
 Multi-Protocol Reader Ver. 2: Operating Instructions 
 
Confidential 
UM 360450-210 Revision: A7  
Page 
39 of 282 
© Kapsch TrafficCom Canada Inc. 2013 
These drawings and specifications contain confidential and proprietary information and are the property of Kapsch TrafficCom  Canada Inc. and are issued in strict 
confidence and will be kept confidential and used solely for the purpose intended and for no other purpose and shall not be transmitted, reproduced, copied, and/or 
used as the basis for manufacture or sale of apparatus unless otherwise agreed to in writing by Kapsch TrafficCom Canada Inc. 
 
FILE: UM 360450-210 OPERATIONS AND MAINTENANCE MANUAL.DOCX 
 
10/31/2013 7:56 
 
Kapsch TrafficCom 
3.
 O
PERATING 
P
ROCEDURES
 
 
CAUTION:
 
Improper  modification  of  configuration  parameters  may  adversely 
affect system operation. The default values may not be appropriate for 
the  specific  application.  It  is  the  system  integrator’s  responsibility  to 
tailor  the  configuration  parameters  to  the  specific  operating 
environment, with the aid of Kapsch’s Operations Group.
 
 
 
CAUTION: Redundant Reader
 
Both CTMs in a redundant Reader must be properly configured. Each 
CTM  has  its  own  browser  interface  and  is  configured  independently. 
Ensure any configuration changes made to one CTM are applied to the 
other CTM, as required
Starting up the Reader 
This procedure outlines the correct way to power on and boot up a Reader. 
Prerequisites:   PSM power switches set to the off (0) position. 
1. CTM ON/OFF switches set to OFF. 
2.  Set the Redundancy Mode switch on the SPM to AUTO. 
3.  Set the secondary and primary PSM power switches to the 
on (I) position.  
Result: The +15V STATUS LED and the +5 STATUS LED on the PSMs illuminate solid green. 
4.  Set the CTM ON/OFF switch to the ON position, and wait for the CTM to complete its power up cycle 
(approximately 120 Seconds). 
Result: The POWER LED illuminates green. The STATUS LEDs illuminate green to indicate SYNC is 
functional, CTM is active, CGC is functional and MC is functional. 
Note: If any CTM STATUS LEDs indicate an abnormal state, (see Table 6-1: CTM LED states explained on 
page 184) perform the necessary troubleshooting procedure. See Troubleshooting Methodology on page 182 
for more information.
Shutting down the Reader 
This procedure outlines the correct way to power down a Reader. 
Prerequisites: None. 
1.  Set both CTM ON/OFF switches to OFF.