Description: 
   Electrical Specification
SilverStone Technology Co., Ltd. 
 
Subject: 
SilverStone Technology 
Model: ST85ZF 
Switching Power Supply 
 
 
Document No.: 
   ES-850-ZEUS-01 
File Name: ST85ZF.doc                                           Page :  10    
  
 
6. Agency Requirements 
6.1 Safety Certification.
 
Product Safety:   
UL 60950 2000Edition, IEC60950, 3
rd
 Edition 
EU Low Voltage Directive(73/23/EEC) (CB) 
TUV, CCC 
RFI Emission: 
FCC Part15 (Radiated & Conducted Emissions) 
CISPR 22,3
rd
 Edition/ EN55022 Class B) 
PFC Harmonic: 
EN 61000-3-2 
Flicker: 
EN 61000-3-3 
Immunity against: 
-Electrostatic discharge: 
 
-Radiated field strength: 
-Fast transients: 
 
-Surge voltage: 
 
-RF Conducted 
-Voltage Dips and Interruptions 
EN55024: 1998 
-IEC 61000-4-2 Min. 4kV contact discharge 
                          Min. 8kV air discharge 
-IEC 61000-4-3 Min. 10V/m 
-IEC 61000-4-4 Min 2kV AC input lines 
                          Min 1kV on data lines 
-IEC 61000-4-5 Min 2kV common mode 
                          Min 1kV differential mode 
-IEC 61000-4-6 
-IEC 61000-4-11   
 
Table 16 –
Safety Certification
 
 
6.2 AC Input Leakage Current 
Input leakage current from line to ground will be less than 3.5mA rms. Measurement will be made at 
240 VAC and 60Hz. 
6.3 Production Line Testing 
100% of the power supply production must have the following test performed. Each power shall be marked 
indicating the testing was done and passed. Typically this is done by stamping or labeling the power supply 
with “Hi-pot test OK”. 
 
 
6.4 Hi-Pot Testing 
Each power supply must be Hi-pot tested according UL and TUV requirements, Minimum typical testing 
voltage for Hi-pot testing are 1500Vac or 2121Vdc.    However depending on the power supply design the 