Silverstone ST85ZF SST-ST85ZF User Manual
Product codes
SST-ST85ZF
Description:
Electrical Specification
SilverStone Technology Co., Ltd.
Subject:
SilverStone Technology
Model: ST85ZF
Switching Power Supply
Document No.:
ES-850-ZEUS-01
File Name: ST85ZF.doc Page : 10
6. Agency Requirements
6.1 Safety Certification.
Product Safety:
UL 60950 2000Edition, IEC60950, 3
rd
Edition
EU Low Voltage Directive(73/23/EEC) (CB)
TUV, CCC
RFI Emission:
FCC Part15 (Radiated & Conducted Emissions)
CISPR 22,3
rd
Edition/ EN55022 Class B)
PFC Harmonic:
EN 61000-3-2
Flicker:
EN 61000-3-3
Immunity against:
-Electrostatic discharge:
-Radiated field strength:
-Fast transients:
-Surge voltage:
-RF Conducted
-Voltage Dips and Interruptions
EN55024: 1998
-IEC 61000-4-2 Min. 4kV contact discharge
Min. 8kV air discharge
-IEC 61000-4-3 Min. 10V/m
-IEC 61000-4-4 Min 2kV AC input lines
Min 1kV on data lines
-IEC 61000-4-5 Min 2kV common mode
Min 1kV differential mode
-IEC 61000-4-6
-IEC 61000-4-11
Table 16 –
Safety Certification
6.2 AC Input Leakage Current
Input leakage current from line to ground will be less than 3.5mA rms. Measurement will be made at
240 VAC and 60Hz.
6.3 Production Line Testing
100% of the power supply production must have the following test performed. Each power shall be marked
indicating the testing was done and passed. Typically this is done by stamping or labeling the power supply
with “Hi-pot test OK”.
6.4 Hi-Pot Testing
Each power supply must be Hi-pot tested according UL and TUV requirements, Minimum typical testing
voltage for Hi-pot testing are 1500Vac or 2121Vdc. However depending on the power supply design the
testing voltage May be higher. If higher the power supplies shell be at the higher value.
100% of the power supply production must have the following test performed. Each power shall be marked
indicating the testing was done and passed. Typically this is done by stamping or labeling the power supply
with “Hi-pot test OK”.
6.4 Hi-Pot Testing
Each power supply must be Hi-pot tested according UL and TUV requirements, Minimum typical testing
voltage for Hi-pot testing are 1500Vac or 2121Vdc. However depending on the power supply design the
testing voltage May be higher. If higher the power supplies shell be at the higher value.