 6–38  Installing indoor hub equipment
Hub installation
3.
Also observe the CCM startup diagnostics (SUDS) on the
CCM’s front panel LCD:
(For the tests and status checks described in this chapter, the
HT does not have to be connected to the EMS.)
SUDS start on powerup. While they run, the CCM front
panel shows the following messages, in the sequence
shown.
Equipment function is normal when you see the
messages shown below and no failure messages.
Initial powerup
SUDS CPU Reg  OK
SUDS DRAM       OK
CPU registers and dynamic 
RAM are tested.
Timer test
SUDS  Timer Test
Timers are tested.
Watchdog timer test
SUDS    WDT Test
The watch dog timer 
is tested.
PCI test
SUDS    PCI Test
The PCI controller is tested.
Static dual port RAM test
SUDS SDPRAM Test
Static dual port RAM is tested.
Serial port 1 test
SUDS  Ser 1 Test
Serial port 1 is tested.