Panic Keys Audible is enabled, the system will beep the keypad 
three times upon activation and activate the alarm output until a 
code is entered or the alarm output times out. Otherwise the 
alarm will be completely silent.
NOTE:
The Fire, Auxiliary, Panic keys will operate even if 
Keypad Lockout is active (see section 4.13 “Keypad Options” 
on page 14).
Fire Keys Enable  . . . . . . . . . . . . . . . . . Section [015], Option [1] 
Panic Keys Audible . . . . . . . . . . . . . . . Section [015], Option [2] 
Fire Bell Continuous  . . . . . . . . . . . . . . Section [014], Option [8]
4.13 Keypad Options
The system can be programmed to ‘lockout’ keypads if a series of 
incorrect access code entries are made. After the Number of 
Invalid Codes Before Lockout 
has been reached the system 
will lock out the keypad for the
 
Lockout Duration and log the 
event to the event buffer. For the duration of the lockout the sys-
tem will sound an error tone when any key is pressed. The invalid 
code counter will be reset every hour.
To disable Keypad Lockout program the Number of Invalid 
Codes Before Lockout
 as (000).
NOTE:
 If Keypad Lockout is active, the system cannot be 
armed or disarmed with a keyswitch.
If the Keypad Blanking Option is enabled the system will turn 
off all lights on the NT9010 if no key is pressed for 30 seconds. 
The keys, however, will remain backlit.
The system will turn the NT9010 lights back on if entry delay 
begins or an audible alarm occurs. If the Code Required to 
Restore Blanking Option
 is enabled, the lights will turn on 
when a valid access code is entered. Otherwise, the lights will 
turn on when a key is pressed.
NOTE:
 Keypad function keys will still operate when the 
keypad is blank, unless the function key is programmed to 
require an access code.
The keys of all the keypads can be backlit to provide easy viewing 
in dim lighting conditions. If the Keypad Backlighting Option 
is enabled the keys will be illuminated.
If the Bypass Status Displayed While Armed option is chosen, 
the System light will be ON while the system is armed to indicate 
that there are bypassed zones.
Number of Invalid Codes Before Lockout  . . . . . . . Section [012]
Lockout Duration . . . . . . . . . . . . . . . . . . . . . . . . . Section [012]
Keypad Blanking Option . . . . . . . . . . . Section [016], Option [3]
Code Required to Restore Blanking. . . Section [016], Option [4]
Keypad Backlighting Option . . . . . . . . Section [016], Option [5]
Bypass Displayed While Armed . . . . . . Section [016], Option [7]
Keypad Lockout Reporting Code  . . . . . . . . . . . . . Section [338]
4.14 Sleep Mode
To conserve the backup battery during the loss of AC power, the 
NT9010 control unit will enter “sleep mode” after AC power is 
missing for 30 seconds. When the NT9010 is in sleep mode, all 
the lights on the unit will turn off, except for the System light, 
which will flash.
The system will “wake up” and run on the backup battery when 
any system event occurs, or when a user presses and holds a but-
ton on the unit for 2 seconds.