Digital Security Controls Ltd. 01NB9010 User Manual

Page of 68
C h a p t e r   1 :   Q u i c k   S e t   U p
1 0
1.2.6
Mounting 
the Wireless 
Devices
Do not permanently mount the wireless devices until you have completed the 
Placement Tests (see 1.2.7 Enrolling Devices and Setting Up the System on 
page 10). Once you have a good location for each of the devices, follow the 
mounting instructions on the Installation Instruction sheet for each device. For 
WLS904P-433, see Appendix D: WLS904P Wireless Motion Detector Installa-
tion Instructions
 on page 62. For WLS925L-433, see Appendix C: WLS925L-433 
Mini Door/Window Contact Installation Instructions
 on page 61.
1.2.7
Enrolling 
Devices and 
Setting Up 
the System
Flash Programming will guide you through the steps needed to set up each zone and 
basic system programming. If you need to perform more advanced programming for 
your installation, please see Chapter 2: Advanced Programming on page 15. 
To access Flash Programming:
1. Press [✱][8].
2. Enter the Installer’s code. The Installer Code is [5555] at default, but should be 
changed to prevent unauthorized access to programming.
3. Press [1] to enter Flash Programming.
4. Follow the audio instructions announced by Flash Programming. Flash Program-
ming will guide you through the following programming areas:
Device enrollment
Zone label assignment
Central station telephone number
System account code
Placement tests of each wireless device
You can use the Forward (Playback) button to advance to the next section in 
Flash Programming, and the Backward (Record) button to return to the previous 
section.
5. Be sure to record all the zone serial numbers and your programming choices in 
the NT9010 Programming Worksheets
Here are some notes about system programming done through Flash Programming.
Zone Definitions
When you enter a serial number for a device into the NT9010 Flash Programming, 
the unit will analyze the number to determine what kind of device you are enroll-
ing. Based on the type of device, the system will make the following programming 
choices:
Device Type
Zone Definition
Other Programming
Door/window contact 
(2XXXXX, including hard-
wired contacts entered as 
200001 and 200002)
Delay 1 (Type [01])
For hardwired zones (serial 
numbers 200001 and 
200002), Zone Supervision 
disabled (section [804])
Motion or glassbreak 
detector (3XXXXX)
Interior Stay/Away 
(Type [05])
None
Smoke detector 
(4XXXXX)
Delayed 24 Hour Fire 
(Type [87])
None
Wireless key (6XXXXX)
None
None