Digital Security Controls Ltd. 01NB9010 User Manual

Page of 68
C h a p t e r   1 :   Q u i c k   S e t   U p
1 2
Programming Zone Labels
If an enrolled device is a door/window contact, motion detector, glassbreak detec-
tor, or smoke detector the system will then prompt you to enter an audio label for 
the new zone. You can choose from any of the following preset audio labels:
If necessary, you can also program custom labels for the zones through the NT9010 
Flash Programming. 
1. For door/window contacts, motion detectors, and glassbreak detectors, at the 
appropriate place in Flash Programming, instead of selecting labels A to E, press 
function key F.
2. You can now enter up to six pre-programmed words from the Audio Label 
Library. For each word you want to program, enter a 3-digit code from the Label 
Library (for a list of labels and codes, see the NT9010 Programming Worksheets
Appendix A). If your label is less than six words, press [#] at the end of the label.
3.  If you want to use a recorded label instead of the words available in the Audio 
Label Library, enter [244] for the first label entry, then the number of the label 
[001] to [005]. The recorded label will replace all six words in the section. You 
will not be able to add additional words to the label. To record a label for a 
zone, please see section 2.1.5 Programming Audio Labels on page 16.
4. When you have entered the label, the system will recite it. If the label is correct, 
press [1]. If the label is not correct, press [2] and repeat steps 1 to 3 to fix the label.
NOTE:
You must accept a label to exit this section. If you choose F for a 
custom label, then you must create your own label using the Audio Label 
Library and accept it.
NOTE:
If you chose one of the audio labels, section [001] to [005] (#3 
above) and there is no audio label recorded, the label will default to “zone 
X” where “X” is the zone number of the device enrolled. When the label is 
recorded in section [807], [701] to [705] it will be used.
Entering the Central Station Telephone Number
When prompted, enter the telephone number for the central station. The number 
can be up to 32 digits long. When you program the number, the system automati-
cally inserts the hexadecimal digit “D” at the beginning, to tell the system to con-
Press 
Function 
Key:
Door/window 
contacts 
(2XXXXX)
Motion or 
glassbreak 
detector 
(3XXXXX)
Smoke detector 
(4XXXXX)
A
Front door
Main floor motion
Main floor fire
B
Back door
Upstairs motion
Upstairs fire
C
Garage door
Downstairs motion
Downstairs fire
D
Window
Hallway motion
Hallway fire
E
Patio door
Garage motion
Garage fire