Digital Security Controls Ltd. 01NB9010 User Manual
1 5
Chapter 2: Advanced Programming
Section 2.1: Programming the NT9010
The chapter describes how to use advanced programming. For instructions on using Flash Programming, please
see Chapter 1: Quick Set Up Guide.
see Chapter 1: Quick Set Up Guide.
2.1.1
How to Enter
Advanced
Programming
Advanced
Programming
You can use the Advanced Programming to set all communicator and system
options. The Installer Code is [5555] at default, but should be changed to prevent
unauthorized access to programming.
options. The Installer Code is [5555] at default, but should be changed to prevent
unauthorized access to programming.
Step 1: From any keypad enter [✱][8][Installer Code].
• The System light will flash and the Armed light will turn on to indicate you are
in programming
• The NT9010 will announce “To use Flash Programming press 1. To bypass Flash
Programming press 2.”
Step 2: To skip Flash Programming and go to the advanced programming sections,
press [2].
press [2].
Step 3: Enter the 3-digit section number you want to program.
• The Armed light will turn off and the Ready light will turn on to indicate the sys-
tem is ready for the information for the selected section
• You can use the Forward (Playback) button to go forward through the advanced
programming data. The Backward (Record) button will not work in the
advanced programming sections, except for sections [301] to [303], and [402].
advanced programming sections, except for sections [301] to [303], and [402].
Step 4: Sections [802], [804], or [807] have 2- or 3-digit sub-sections. To access
programming in these sections enter the programming sub-section number.
programming in these sections enter the programming sub-section number.
NOTE:
If the section number entered is not valid, the NT9010 will sound
an error tone and say the section number that was entered.
Installer Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Section [006]
2.1.2
Programming
Decimal Data
Decimal Data
When the Ready light is ON the NT9010 is waiting for the information to be pro-
grammed for the selected section.
grammed for the selected section.
If a digit is entered for each program box in a section the system will automatically
exit from the section. It will turn OFF the Ready light and turn the Armed light back
ON.
exit from the section. It will turn OFF the Ready light and turn the Armed light back
ON.
You can also press the [#] key to exit a section before entering data for every box.
This is handy if you only need to change the first few program boxes. All other loca-
tions in the section will remain unchanged. If the [#] key is pressed the system will
turn OFF the Ready light, turn ON the Armed light and exit from the section.
This is handy if you only need to change the first few program boxes. All other loca-
tions in the section will remain unchanged. If the [#] key is pressed the system will
turn OFF the Ready light, turn ON the Armed light and exit from the section.