Digital Security Controls Ltd. 01NB9010 User Manual

Page of 68
1 5
Chapter 2: Advanced Programming
Section 2.1: Programming the NT9010
The chapter describes how to use advanced programming. For instructions on using Flash Programming, please 
see Chapter 1: Quick Set Up Guide.
2.1.1
How to Enter 
Advanced 
Programming
You can use the Advanced Programming to set all communicator and system 
options. The Installer Code is [5555] at default, but should be changed to prevent 
unauthorized access to programming.
Step 1: From any keypad enter [✱][8][Installer Code].
• The System light will flash and the Armed light will turn on to indicate you are 
in programming 
• The NT9010 will announce “To use Flash Programming press 1. To bypass Flash 
Programming press 2.”
Step 2: To skip Flash Programming and go to the advanced programming sections, 
press [2].
Step 3: Enter the 3-digit section number you want to program.
• The Armed light will turn off and the Ready light will turn on to indicate the sys-
tem is ready for the information for the selected section
• You can use the Forward (Playback) button to go forward through the advanced 
programming data. The Backward (Record) button will not work in the 
advanced programming sections, except for sections [301] to [303], and [402].
Step 4: Sections [802], [804], or [807] have 2- or 3-digit sub-sections. To access 
programming in these sections enter the programming sub-section number.
NOTE:
 If the section number entered is not valid, the NT9010 will sound 
an error tone and say the section number that was entered.
Installer Code  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Section [006]
2.1.2
Programming 
Decimal Data
When the Ready light is ON the NT9010 is waiting for the information to be pro-
grammed for the selected section. 
If a digit is entered for each program box in a section the system will automatically 
exit from the section. It will turn OFF the Ready light and turn the Armed light back 
ON.
You can also press the [#] key to exit a section before entering data for every box. 
This is handy if you only need to change the first few program boxes. All other loca-
tions in the section will remain unchanged. If the [#] key is pressed the system will 
turn OFF the Ready light, turn ON the Armed light and exit from the section.