S e c t i o n   2. 2:  C h an g i n g   H o w   t h e   N T 90 1 0   W o r k s   F o r  U s e r s
2 3
tem [✱] command prompts: if a prompt is disabled, users will still be able to enter 
the command it refers to.
Sub-section [003] determines which Status prompts the user will hear. If an option 
is “ON”, the system will announce the prompt when the appropriate condition is 
present. If an option is “OFF”, the system will not announce the prompt if the con-
dition is present. For example, if you turn off the “Zone Tamper” prompt, when a 
zone is tampered on the system, the NT9010 system will not announce it to the 
user.
You can also have the NT9010 system announce the names of zones that are 
opened or closed by turning on the Verbal Chime option. When this option is 
turned on, if the Verbal Chime for Zone Openings is also enabled, whenever a 
zone with the Chime attribute enabled is opened, a series of beeps will sound and 
the NT9010 will prompt (for example):
“Front Door”
If the Verbal Chime for Zone Closings is enabled, the NT9010 system will 
announce the zone label when the zone is closed. See also [*] [4] Door Chime On/
Off
 on page 29.
You can create custom labels for the system and for each zone in the Labels pro-
gramming area. Please see 2.1.5 Programming Audio Labels on page 16 for 
more information.
Clock is AM/PM . . . . . . . . . . . . . . . . . . . . . . . . . . . .Section [807]-[002], Option [1]
System Status Prompts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  Section [807]-[003]
[✱] Command Prompts  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  Section [807]-[004]
Door Chime Zone Attribute . . . . . . . . . . . . . . . . Sections [101] to [132], Option [3]
Verbal Chime Enabled/Disabled . . . . . . . . . . . . . . . . . . . .  Section [017], Option [2]
Verbal Chime for Zone Openings . . . . . . . . . . . . . . .Section [807]-[002], Option [2]
Verbal Chime for Zone Closings . . . . . . . . . . . . . . . .Section [807]-[002], Option [3]
Custom Zone Labels  . . . . . . . . . . . . . . . . . . . . .Sections [807]-[601] to [807]-[632]
2.2.4
Alarm 
Announce-
ments
If the Verbal Alarm option is turned on, the system will announce the first and last 
zones that have gone into alarm, along with the alarm tone. When a zone with the 
Audible attribute turned on goes into alarm, the NT9010 system will sound an 
alarm tone, but every 15 seconds it will pause the siren and the speaker will 
announce the zone(s) in alarm, for example:
“Alarm South Bedroom Window”
You can change the number of seconds between alarm announcements in the 
Alarm Tone Period for Verbal Alarm section.
Zones programmed as Silent, and 24 Hour Supervisory Buzzer zones will not be 
announced or cause the unit to annunciate at full volume. 
NOTE:
 Fire annunciation always overrides any burglary zone alarm 
annunciation. Alarms from Fire or Panic keys override all other alarm 
announcements.