Digital Security Controls Ltd. 01NB9010 User Manual

Page of 68
C h a p t e r   2 :   A d v a n c e d   P r o g r a m m i n g
2 4
NOTE:
The alarm announcements will stop with the siren at the end of 
the Bell Time Out period.
Verbal Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  Section [017], Option [3]
Alarm Tone Period for Verbal Alarm . . . . . . . . . . . . . . . . . . . . . .Section [807]-[030]
2.2.5
Arming and 
Disarming 
Options
If the Arm/Disarm Bell Squawk option is enabled the system will squawk the 
alarm output once upon arming and twice upon disarming. If an alarm is in mem-
ory, when the system is disarmed the bell will sound three pairs of disarm squawks. 
NOTE:
 If you enable the Bell Squawk on Arming/Disarming (section 
[014], option [1]), the bell will sound arm/disarm bell squawks for all access 
codes, regardless of the programming for attribute [7] (see 2.2.2 Access 
Codes 
on page 20).
Enable both the Squawk on Away Arming/Disarming Only and the Arm/Dis-
arm Bell Squawk
 options to have the system squawk the bell only when the sys-
tem is away armed or disarmed.
If the Opening After Alarm Keypad Ringback option is turned on, the system 
will beep the keypad 10 times rapidly if the system is disarmed after an alarm 
occurred. If the Opening After Alarm Bell Squawk option is turned on, the sys-
tem will squawk the bell output 10 times rapidly if the system is disarmed after an 
alarm occurred.
If the system is armed using the Stay function key, or by entering [✱][9][access 
code], there will be no bell squawks during entry and exit delays, except for the 
arm/disarm bell squawks.
Closing Confirmation, if enabled, will cause the keypad to beep 10 times rapidly 
after the closing reporting code has been successfully transmitted to central station.
If the AC/DC Inhibit Arming option is enabled, the system will not arm if there is 
an AC or DC (battery) trouble present on the system. Arming will not be allowed 
until the AC or battery trouble is cleared. If no AC or battery trouble is currently 
present, when a user attempts to arm the system, the system will do an automatic 
battery test. If the battery is good, the system will arm. If the battery is bad, the sys-
tem will not arm.
If the AC/DC Inhibit Arming option is disabled, the system will not do an automatic 
battery test when arming is attempted and the user will not be prevented from 
arming the system when there is an AC or battery trouble.
If you enable the WLS Key Does Not Use Access Codes option, the disarm but-
ton will work on wireless keys which have not been assigned access codes.
To prevent disarming by wireless keys which don’t have access codes, disable this 
option. (See also 2.2.11 Programming Wireless Keys on page 33.)
Arm/Disarm Bell Squawk . . . . . . . . . . . . . . . . . . . . . . . . .  Section [014], Option [1]
WLS Key Does Not Use Access Codes  . . . . . . . . . . . . . . .  Section [017], Option [1]
Bell Squawk on Away Arming . . . . . . . . . . . . . . . . . . . . .  Section [017], Option [8]
Opening After Alarm Keypad Ringback . . . . . . . . . . . . . .  Section [381], Option [1]