C h a p t e r   2 :   A d v a n c e d   P r o g r a m m i n g
3 4
If the Fire Keys option is enabled, when the Fire keys are pressed and held for 2 
seconds, the system will activate the alarm output. It pulses one second on, one 
second off only if option 8 of Section [013] is disabled (Standard Fire option). If Fire 
Bell Continuous
 is selected the alarm output will sound until a code is entered; 
otherwise it will sound until a code is entered or the alarm output times out. Com-
munication of the signal to central station is immediate.
If the Auxiliary Keys are pressed and held for 2 seconds, the unit beeps three times 
to verify activation. The system will beep the keypad ten times rapidly to verify 
communication to the central station.
If the Panic Keys are pressed and held for 2 seconds, the system will immediately 
communicate the signal to central station. If Panic Keys Audible is enabled, the 
system will beep the keypad three times upon activation and activate the alarm 
output until a code is entered or the alarm output times out. Otherwise the alarm 
will be completely silent.
NOTE:
The Fire, Auxiliary, Panic keys will operate even if Keypad Lockout 
is active (see 2.2.13 Keypad Options on page 34).
Fire Keys Enable. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  Section [015], Option [1] 
Panic Keys Audible  . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  Section [015], Option [2] 
Fire Bell Continuous. . . . . . . . . . . . . . . . . . . . . . . . . . . . .  Section [014], Option [8]
2.2.13 Keypad 
Options
The system can be programmed to ‘lockout’ keypads if a series of incorrect access 
code entries are made. After the Number of Invalid Codes Before Lockout has 
been reached the system will lock out the keypad for the
 
Lockout Duration and 
log the event to the event buffer. For the duration of the lockout the system will 
sound an error tone when any key is pressed. The invalid code counter will be reset 
every hour.
To disable Keypad Lockout program the Number of Invalid Codes Before Lock-
out
 as (000).
NOTE:
 If Keypad Lockout is active, the system cannot be armed or dis-
armed with a keyswitch.
If the Keypad Blanking Option is enabled the system will turn off all lights on the 
NT9010 if no key is pressed for 30 seconds. The keys, however, will remain backlit.
The system will turn the NT9010 lights back on if entry delay begins or an audible 
alarm occurs. If the Code Required to Restore Blanking Option is enabled, the 
lights will turn on when a valid access code is entered. Otherwise, the lights will 
turn on when a key is pressed.
NOTE:
 Keypad function keys will still operate when the keypad is blank, 
unless the function key is programmed to require an access code.
The keys of all the keypads can be backlit to provide easy viewing in dim lighting 
conditions. If the Keypad Backlighting Option is enabled the keys will be illumi-
nated.
If the Bypass Status Displayed While Armed option is chosen, the System light 
will be ON while the system is armed to indicate that there are bypassed zones.