2.3.10 Communicator 
Account 
Codes
The system Account Codes will be used by the NT9010 when communicating sys-
tem events (e.g. Low Battery, Test Transmission). This account code can be up to 
four digits in length. 
You can program two account codes: one for the first and third telephone num-
bers, and one code for the second telephone number. You can also program the 
Telephone Number 1/3 Account Code in Flash Programming (see the Quick Set Up 
Guide
).
Telephone Number 1/3 Account Code . . . . . . . . . . . . . . . . . . . . . . . . Section [310]
Telephone Number 2 Account Code  . . . . . . . . . . . . . . . . . . . . . . . . . Section [311]
2.3.11 Communicator 
Reporting 
Formats
You can program the NT9010 system to report events using any one of the 5 for-
mats available. The system can report using different formats for Telephone Num-
bers 1/3, and for Telephone Number 2. The following formats are supported: Pulse 
(20bps), Contact ID, SIA, and a Pager format. The following is a description of 
each.
Communicator Format Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Section [350]
Pulse Formats
Depending on the pulse format selected the system will communicate using the 
following:
• 3/1, 3/2, 4/1 or 4/2
• 1400 or 2300 Hz handshake
• 20bps 
• non-extended
With the 1600Hz Handshake option enabled, the communicator will respond to 
1600Hz handshakes when using the reporting Communication Formats 01 and 02 
only. When the Standard Handshake option is enabled, the communicator will 
respond to the handshake specified by the BPS format (1400Hz or 2300Hz).
Additional Notes on Pulse Formats
1. The digit ‘0’ will send no pulses and is used as a filler.
2. When programming account numbers enter four digits.
3. When programming a three digit account number the fourth digit must be pro-
grammed as a plain ‘0’ which will act as a filler digit.
4. If an account number has a ‘0’ in it, substitute the HEX digit ‘A’ for the ‘0’. 
Examples:
3 digit account number [123] - program [1230]
3 digit account number [502] - program [5A20]