5 2
If the Full 6-hour User Enabled DLS Window option is enabled, when the user 
opens the DLS window with [✱][6][Master code][5], the DLS window will remain 
open for six hours. The DLS window will remain open after a successful hang-up 
from a downloading call. If the One Time 1-hour User Enabled DLS Window 
option is enabled, when the user opens the DLS window with [✱][6][Master 
code][5], the DLS window will stay open for one hour, and will close after a suc-
cessful hang-up from a downloading call.
Except for the first six hours after power up, the system will not answer incoming 
calls unless the Answering Machine/Double Call option is enabled, or the Num-
ber of Rings
 is programmed to be more than [0].
If the User-Initiated Call-Up option is enabled, the user can have the system ini-
tiate a call to the downloading computer by pressing [✱][6][Master Code][6].
The Download Access Code and Panel Identifier Code are for security and 
proper identification. Both the system and the computer file should have the same 
information programmed before attempting to download.
The time to complete a successful download can be significantly reduced with the 
use of the PC-Link adaptor. This adaptor makes it possible to perform on-site 
downloading.
To perform PC-LINK please do the following:
• Set up the downloading computer close to where the NT9010 is installed.
• Remove the NT9010 from the top two latches and allow the unit to sit at a 90 
degree angle to the backplate. The unit may also be completely removed from 
the backplate.
• Connect the PC-LINK header in the slot provided in the back of the unit.
• Ensure that the downloading computer has initiated the PC-LINK session.
To Initiate Local Downloading via PC-Link, enter [
] [8] [Installer’s Code] [499] 
[Installer’s Code] [499]. The keypad will be busy for the duration of the PC-Link 
connection. The status LEDs will display the current system status. For more infor-
mation on connecting the PC-Link adaptor, refer to your “PC-Link Download Kit 
Instruction Sheet”.
Answering Machine/Double Call . . . . . . . . . . . . . . . . . . .  Section [401], Option [1]
User Enable DLS Window  . . . . . . . . . . . . . . . . . . . . . . . .  Section [401], Option [2]
Call Back . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  Section [401], Option [3]
User-Initiated Call-up . . . . . . . . . . . . . . . . . . . . . . . . . . . .  Section [401], Option [4]
Answering Machine Double Call Timer  . . . . . . . . . . . . . . . . . . . . . . . Section [405]
Download Computer Telephone Number  . . . . . . . . . . . . . . . . . . . . . Section [402]
Download Access Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Section [403]
Panel Identifier  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Section [404]
Standard/UL Communications Priority  . . . . . . . . . . . . . . .  Section [701], Option [8]
One-time 1-hour user enabled DLS window. . . . . . . . . . .  Section [702], Option [7]