Digital Security Controls Ltd. 02RF5501433 User Manual

Page of 32
13
To program the wireless supervisory window:
1. Enter [
✱][8][Installer Code] to enter Installer Programming.
2. Enter [804] to enter into Receiver Programming.
3. Enter sections [81].
4. Enter the time period for the supervisory window (8 to 24 hours).
5. To exit press [#].
Disable/Enable Zone Supervision
All wireless zones have supervision enabled by default. To disable supervision for any
zone, enter the following at any system keypad:
1. Enter [
✱][8][Installer Code] to enter Installer Programming.
2. Enter [804] to enter the PC5132 Module Programming.
3. Enter sections [82], [83], [84] and [85]. Disable or enable supervision for each
wireless zone by turning each relevant option on or off.
4. To exit press [#].
4.4 RF Jam Detect Zone
For RF jamming detection to work, you must select an unused zone to be used as the
RF Jam Detect zone. When the receiver detects an attempt to jam the RF signal, the
RF Jam Detect zone will be violated and the system will generate a tamper signal. When
the jamming signal is gone, the RF Jam Detect zone closes and the system sends a
tamper restore signal.
To enable RF jamming detection:
1. Enter [
✱][8] [Installer’s Code].
2. Enter programming section [804].
3. Enter section [93]. Enter the 2-digit number of the RF Jam Detect zone ([01] to
[32]) in the programming section.
4. Disable supervision for the RF Jam detect zone by turning the relevant option off in
section [82], [83], [84] or [85]. (See section 4.3 for more information.)
5. RF jamming detection is now enabled. To exit Installer programming, press [#].
4.5  Receiver Software Default
Returning the receiver programming to factory default settings is a quick way to
remove all the enrolled devices from the system and reset all the programming in
section [804].
NOTE: Performing this procedure will not change any programming sections except
[804]. Resetting the control panel to factory default settings will not return the PC5132
to factory default settings.
To restore the PC5132 programming to the factory default settings, perform the
following:
1. Enter [
✱][8] [Installer’s Code].
O  T  H  E  R    P  R  O  G  R  A  M  M  I  N  G