Digital Security Controls Ltd. 03RF5108 User Manual

Page of 24
5
• The RF5108 output can be programmed to follow a main panel output which can turn on
lights when the panel is armed and turn them off when disarmed, turn on lights when an
alarm occurs and turn them off when disarmed, etc. Please refer to the control panel
Installation Manual for a listing of available output types and their function. PGM 1 and/
or PGM 2 on the RF5108-433 can be set up for this operation (see Section 3.5).
After you have completed the wiring, reconnect the power to the security system.
Now that you have wired the RF5108-433, you should enroll and program the wireless
devices. See section 3 for instructions.
Section 3: Enrolling Wireless Devices
This section describes how to enroll wireless devices and wireless keys. For more
information on these devices, read the instruction sheet included with each device.
3.1 A Note about Electronic Serial Numbers
An electronic serial number (ESN) is printed on the back of each wireless device. ESNs are
used to enroll the wireless devices with the RF5108-433 receiver.
In order to reduce the occurrence of wireless devices with the same serial number, 6-digit
serial numbers are now printed on the back of each wireless device. The 6-digit serial
numbers include hexadecimal digits. For instructions on programming hexadecimal
numbers, see your system 
Installation Manual
, section 4: ‘How to Program’.
NOTE: 6-digit serial numbers are only supported on the following control panels:  PC5020,
PC501X,  PC1555, PC1565 and PC580, PC585 v2.0 and higher.
The WLS904L/904PL-433, WLS906-433, WLS907T-433, WLS912L-433, WLS914-433,
WLS918-43 and WLS925L-433 devices have both a 5-digit and a 6-digit serial number
printed on them. When connecting the RF5108-433 to a PC5010 v1.x panel, enter 5-digit
serial numbers only. When connecting the RF5108-433 to a PC5015 v2.x and higher,
PC5020, PC5010, PC1555/1565, or PC580/585 panel enter the 6-digit serial number.
3.2 Enrolling Wireless Devices
1.
At a system keypad, enter [✱][8][Installer’s code] to go to the Installer Programming
section.
2.
Enter programming section [804].
3.
Enter the 2-digit number corresponding to the zone the device is to occupy ([01] to [32]).
NOTE: Hardwired and wireless devices cannot be assigned to the same zone. PC5108
zone expander modules occupy zones in 2 groups of 4 (e.g. zones 9-12 and zones 13-16).
None of the zones assigned to a PC5108 module may be used for wireless devices. For
more information on zone assignment, consult your system Installation Manual.
4.
Enter the device’s ESN. Follow the instructions in section 3.1 above.
5.
Record the serial number and the assigned zone number in the programming
worksheets in the back of this manual.
6.
Repeat steps 3 - 5 until you have enrolled up to 8 wireless devices.
NOTE: The RF5108-433 supports programming of 8 wireless devices that can be assigned
to any of zones 1 to 32 or RF Jam Zone.  Once 8 wireless devices have been programmed
the RF5108-433 will not allow further programming.  An error tone will be heard at the
keypad if further programming is attempted
7.
To exit press [#]. The device is now enrolled on the system.
NOTE: The devices will not work properly until you complete zone and partition program-
ming (see section 4).
S E T U P & W I R I N G