 Receiver Programming
S E C T I O N  3
Enroll & Program Devices
This section describes how to enroll and program:
• wireless devices using zones (WLS904PL-433, WLS906-433, WLS907-433, WLS912L-433,
WLS914-433 and WLS925L-433)
• wireless keys (WLS909-433, WLS919-433, WS4939)
For more information on these devices, read the instruction sheet included with each
device.
3.1 Identified Wireless Keys
Reporting by the system of openings/closings by individual wireless keys and
command output [
✱][7] activation by wireless key buttons may be supported on
certain control panels. To do this, the system will reserve access codes 17 – 32 for
wireless keys 01-16 respectively. You must program one access code for each
wireless key (using [
✱][5] access code programming) for this feature to work correctly.
NOTE: Program these access codes on the system after you have connected the
RF5501-433  to the Keybus (see section 2.4).
Refer to your system 
Installation Manual for information on access code programming.
Opening/Closing By Wireless Key Reporting
NOTE: The Identified Wireless Key Closing option is only available with the PC5020,
P-8+,  PC501X v2.0 and higher, P832/DL v2.0 and higher, PC1555(MX), P-6B(MX),
PC580/585 v2.0 and higher, P-48 v2.0 and higher by turning section [015] option 4 off.
To enable the reporting of openings and closings
 by identified wireless keys:
• Make sure the control panel is v2.0 or higher
• Program a valid access code for each key
• Program a closing and opening reporting code for each key’s access code
• Turn off the Quick Arm option in section [015] option [4] of the control panel
programming
To ensure that an 
unidentified wireless key cannot disarm the system, turn off section
[017], option [1] (in the control panel programming). This option is available in control
panels with software version 2.1 or higher.
3.2 Enroll Wireless Devices Using Zones
Enroll wireless devices which use zones (universal transmitters, motion detectors, smoke
detectors, and panic pendants):
1.  At a system keypad, enter [
✱][8][Installer’s code] to go the installer’s programming section.
2.  Enter programming section [804].
3.  Enter the 2-digit number corresponding to the zone the device is to occupy ([01] to [32]).
NOTE: Hardwired and wireless devices cannot be assigned to the same zone. PC5108
zone expander modules occupy zones in 2 groups of 4 (e.g. zones 9-12 and zones 13-
16). None of the zones assigned to a PC5108 module may be used for wireless devices.
For more information on zone assignment, consult your system Installation Manual.