Digital Security Controls Ltd. 05SKY User Manual

Page of 36
14
Section 7 - [803] Skyroute Programming Worksheets 
(PC5020/PC5010/PC580/1PC555/PC5015/P-832/P-48/P-6B/P-832DL)
7.1
Defaulting
A default must be performed before activating the Skyroute transceiver. For UL Listed installations, refer to the compatible control
panel Installation Manual for programming the number of panel attempts. The number of attempts between the Skyroute and the
panel must be between 5 to 10 attempts. The Skyroute transceiver’s default is 3 attempts.
[99]  Section [99] is for software defaulting of the Skyroute module
• Entering 00 will cause a software default of the Skyroute
module to Full Reporting.  
• Entering 11 will cause a software default of the Skyroute
module and Generic reporting with fall-back to Full report-
ing if TLM or FTC trouble occurs.
• Entering 12 will cause a software default of the Skyroute
module and Generic reporting. 
• Entering FF will cause restart of the Skyroute transceiver. 
• Entering 03 will cause a software default of the Skyroute
module and Backup Reporting.
7.2
Basic Programming
Zone Definitions
[01] Zone 1-16 Definitions
[02] Zone 17-32 Definitions
[03] Zone 33-48 Definitions
[04] Zone 49-64 Definitions
I___I___I
00
  Null Zone (Not Used)
12
  24 Hour Holdup*
23
  Maintained Keyswitch Arm*
01
  Delay 1*
13
  24 Hour Gas*
24
  LINKS1000 Answer*
02
  Delay 2*
14
  24 Hour Heating*
25
  Interior Delay*
03
  Instant*
15
  24 Hour Auxiliary*
26
  24 Hour Non-alarm*
04
  Interior*
16
  24 Hour Panic*
27
 Delayed 24 Hour Waterflow
05
  Interior, Stay/Away*
17
  24 Hour Emergency*
28
  Instant 24 Hour Waterflow
06
  Delay, Stay/Away*
18
  24 Hour Sprinkler*
29
  Auto Verified Fire
07
  Delayed 24 Hour Fire (Hardwired)**
19
  24 Hour Water*
30
  Fire Supervisory
08
  Standard 24 Hour Fire (Hardwired)
20
  24 Hour Freeze*
31
  Day Zone*
09
  24 Hour Supervisory
21
  24 Hour Latching Tamper*
87
  Delay 24 Hour Fire (Wireless)**
10
  24 Hour Supervisory Buzzer*
22
  Momentary Keyswitch Arm*
88
  Standard 24 Hour Fire (Wireless)**
11
  24 Hour Burglary*
*For burglary applications only
** For residential fire applications only
Default
Default
Default
Default
00
I___I___I Zone 1
00
I___I___I Zone 5
00
I___I___I Zone 9
00
I___I___I Zone 13
00
I___I___I Zone 2
00
I___I___I Zone 6
00
I___I___I Zone 10
00
I___I___I Zone 14
00
I___I___I Zone 3
00
I___I___I Zone 7
00
I___I___I Zone 11
00
I___I___I Zone 15
00
I___I___I Zone 4
00
I___I___I Zone 8
00
I___I___I Zone 12
00
I___I___I Zone 16
Default
Default
Default
Default
00
I___I___I Zone 17
00
I___I___I Zone 21
00
I___I___I Zone 25
00
I___I___I Zone 29
00
I___I___I Zone 18
00
I___I___I Zone 22
00
I___I___I Zone 26
00
I___I___I Zone 30
00
I___I___I Zone 19
00
I___I___I Zone 23
00
I___I___I Zone 27
00
I___I___I Zone 31
00
I___I___I Zone 20
00
I___I___I Zone 24
00
I___I___I Zone 28
00
I___I___I Zone 32
Default
Default
Default
Default
00
I___I___I Zone 33
00
I___I___I Zone 37
00
I___I___I Zone 41
00
I___I___I Zone 45
00
I___I___I Zone 34
00
I___I___I Zone 38
00
I___I___I Zone 42
00
I___I___I Zone 46
00
I___I___I Zone 35
00
I___I___I Zone 39
00
I___I___I Zone 43
00
I___I___I Zone 47
00
I___I___I Zone 36
00
I___I___I Zone 40
00
I___I___I Zone 44
00
I___I___I Zone 48
Default
Default
Default
Default
00
I___I___I Zone 49
00
I___I___I Zone 53
00
I___I___I Zone 57
00
I___I___I Zone 61
00
I___I___I Zone 50
00
I___I___I Zone 54
00
I___I___I Zone 58
00
I___I___I Zone 62
00
I___I___I Zone 51
00
I___I___I Zone 55
00
I___I___I Zone 59
00
I___I___I Zone 63
00
I___I___I Zone 52
00
I___I___I Zone 56
00
I___I___I Zone 60
00
I___I___I Zone 64