Digital Security Controls Ltd. 05SKY User Manual

Page of 36
12
Section 6 - Programming and Activating a Skyroute
6.1
Defaulting
NOTE: This product must be defaulted BEFORE pro-
gramming/activating.
Select the type of default as follows:
6.1.1 Full Reporting
• Entering 00 in sub-section [99]
1. A complete default of the system is performed
2. All reporting sub-sections, [30] through [78] are automat-
ically programmed as [FF] and will be sent by the Sky-
route transceiver.
6.1.2
Generic Reporting with Fallback to Full Reporting
• Entering 11 in sub-section [99]* 
1. A complete default is performed.
2. Reduced Reporting as follows:
Reduced Reporting
1. Alarm Restoral Reporting Code, sub-sections [34]
through [38], will be automatically programmed to [00],
except the duress alarm.
2. The Keypad and PGM Restorals in section [39] will be
programmed to [00]. Zone Tamper & Restoral reporting
code, sub-sections [40] through [48], will be programmed
to [00]**.
3. Zone Supervisory & Restoral, sub-sections [49] through
[56], will be programmed to [00]**.
4. Zone Low Battery Alarm & Restoral, sub-sections [57]
through [64], will be programmed to [00]***.
5. Keypad Zone Restoral, sub-section [39], last 4 program-
ming locations, will be programmed as [00].
6. Miscellaneous Restoral and Periodic Test in sections [77]
and [78] will be programmed as [00].
In Generic mode, see Appendix A for Generic signals. (See
Section 3 ‘How Does It Work?’ for description of each report-
ing method). 
6.1.3 Generic Reporting
• Entering 12 in sub-section [99]*
1. A complete default is performed
2. Reduced Reporting as indicated above.
In Generic mode, see Appendix A for Generic signals. (See
Section 3 ‘How Does It Work?’ for description of each report-
ing method.) 
6.1.4 Backup Reporting
• Entering 03 in sub-section [99]
1. A complete default is performed.
2. All reporting sub-sections [30] to [78] are automatically pro-
grammed as [FF] and will be sent by the Skyroute Transceiver.
• Entering 13 in sub-section [99].
1. A complete default is performed.
2. The Skyroute will be programmed for backup mode.
6.2
Programming Options
All programming on the Skyroute transceiver is done in the
Installer Programming mode. Refer to the control panel’s
Installation Manual for instructions on how to enter Installer
Programming. From Installer Programming, enter section
[803] to go to the Skyroute programming sections. 
Sub-sections [01] to [22] apply to all other installations. 
6.2.1 Basic Programming  
Zone Definition: Sub-sections [01] to [05]
These sections must be programmed exactly the same as the
main control panel. This allows the Skyroute transceiver to
translate information sent along the Keybus and identify the
proper event. 
NOTE: The Skyroute module will not follow any zone
transmission delays; i.e., any zones programmed with
a delay will be sent immediately by the Skyroute
transceiver.
Configuration Options: Sub-section [06]
• Channel A enable/disable…………..option [1]
This option must be selected when the Cellemetry provider
is an “A” side carrier. 
• Channel B enable/disable…………..option[2]
This option must be selected when the Cellemetry provider
is a “B” side carrier.
• Home system only enable/disable…option[3]
This option must be programmed to ensure that the Skyroute
transceiver is communicating using the proper carrier. When
selected, the transceiver will only use towers with the same
SID (as programmed in section [07]). 
NOTE: For US locations please refer to ‘U.S.A. SID List -
By State’. For Canadian locations please select channel B.
• To activate the Skyroute module in Home mode:
1. Select a channel, A or B, in address 06 (Option 1 or 2)
2. Wait for signal strength.
3. Enter in address 07 the Home SID number in hexadecimal
format.
4. Select Home mode (Option 3) and deactivate A or B chan-
nel in address 06.
NOTE: After changing sub-section [06] or [07] a
restart is required. Enter [*FF] in section [99].
Skyroute transceiver SID (System ID): 
Sub-section [07]
Please refer to the SID table included with the Skyroute mod-
ule to determine the SID number for your area.
Skyroute Test Time: Sub-section [10]
In this section enter the time of the day (24-hour format) you
want the test transmission to be sent.
Test Transmission Day Mask: Section [11]
In this section select the day of the week on which you want
the test transmission to be sent. 
NOTE: This option cannot be used for UL Listed instal-
lations.
* Any reporting code sub-section not mentioned is pro-
grammed as [FF].
** These signals only apply to installations with double EOL.
*** These signals only apply to installations with wireless zone
modules.