Digital Security Controls Ltd. 05SKY User Manual

Page of 36
1
SKYROUTE QUICK INSTALL GUIDE
IMPORTANT: You must be enrolled with CONNECT 24 to activate a Skyroute transceiver. If you are not
already enrolled, please call 1-888-955-5583 in Canada or 1-888-251-7458 in the U.S. at least 24 hours
prior to your first activation.
STEP 1 – DETERMINE BEST SIGNAL LOCATION  
(See Section 5.1)
Connect the Skyroute transceiver to a 7 Ah battery, as described in Section 5.1. Determine the best location for signal strength. If good signal
strength cannot be found, an antenna extension or relocation may be required.
STEP 2 – CONNECT THE SKYROUTE TO THE PANEL  
(See Section 5.13)
Mount and connect the Skyroute to the control panel as shown in Section 5.13.
STEP 3 – PROGRAM THE SKYROUTE  
(See Section 6)
Enter *8 + Installer Code to enter Programming Mode. Go to section [803], and program the following sections:
DEFAULT THE SKYROUTE - Section [99]
Select the Default option as described in Section 6.1 of this manual:
• For FULL REPORTING……………….enter 00 into Section [99]
• For FALLBACK REPORTING….….....enter 11 into Section [99]
• For GENERIC REPORTING………..…enter 12 into Section [99]
• For BACKUP REPORTING………..…enter 03 into Section [99]
The Skyroute module will automatically restart, and default to the new setting.
PROGRAM THE ZONE DEFINITIONS - Sections [01] through [04]
• Program the Zone Definitions as described in Section 6.2.
SELECT THE CELLULAR CHANNEL - Section [06]
The Skyroute transceiver is defaulted for Channel B. If you require Channel A (see the SID List for the channel of the cellular service pro-
vider in your area), perform the following:
• In Section [06], TURN OFF OPTION 2, and TURN ON OPTION 1 (Press # to exit section [06])
• In Section [10], enter the transmission time of day in 24-hour format (HHMM).
NOTE: Due to the volume of wireless traffic generated by test signals, please select a time which is NOT on the :30 minute marks (i.e.,
NOT 02:30, 04:00, etc. Select a time like 02:24, or 04:07, etc. wherever possible.
• In Section [11], select the transmission day of the week.
NOTE: This section is not to be used for UL Listed applications.
• In Section [13], select Daily or Weekly testing as required.
NOTE: Select this option in conjunction with the CONNECT 24 rate plan you are using for this installation. The default setting is
weekly. For UL Listed applications daily test reports are required.
STEP 4 – ACTIVATE THE SKYROUTE WITH CONNECT 24  
(See Section 6.3)
Call the Voice Response Unit (VRU) at the toll free number provided with your Dealer Confirmation.
Once activated, send two signals to your
central station to confirm proper operation.
YOUR SKYROUTE INSTALLATION IS NOW COMPLETE.
ALL OTHER PROGRAMMING SECTIONS IN THIS MANUAL ARE OPTIONAL