Digital Security Controls Ltd. 05SKY User Manual

Page of 36
2
Section 1 - Contents
1.1
Important Information
This manual is based on the production version of the included
wireless device. Software changes may have occurred after the
revision of this manual.
Caution
Any changes or modifications not expressly approved in this
document could void your warranty for this equipment and
void your authority to use this equipment.
Warning
Only use the antenna provided by DSC. The use of any other
type will invalidate the warranty and may be dangerous.
1.2
Skyroute Transceiver Glossary of Terms
The following is a description of various terms used with
respect to cellemetry technology.
Electronic Serial Number (ESN)
The ESN is used to carry data information in a Cellemetry Net-
work 
Mobile Identification Number (MIN)
A 10-digit decimal number used for registrations and pages.
Page
A transmission that is sent from the Cellemetry Gateway to the
Cellemetry radio.
Registration
A transmission that is sent from the Cellemetry radio to the
Cellemetry Gateway.
System Identification Number (SID)
Identification of the Cellemetry Provider.
Switch Number  (SNO)
Switch number the Cellemetry radio uses to transmit pages to
the Cellemetry Gateway.
Clearing House
The clearing house is a routing center that automatically for-
wards data between Skyroute transmitters and central stations.
Section 2 - What is it?
2.1
Introducing the Skyroute Transceiver
The Skyroute transceiver offers a new wireless communication
method for the transmission of event information using the
*Cellemetry
TM
 service. Events are transmitted from the Sky-
route transceiver via the Cellemetry network to the clearing
house and then to the central station in a fast, reliable manner.
The Skyroute  receiver has been designed for simple and
straightforward installation. Using Keybus
TM
 technology, wir-
ing connections are made directly between Skyroute module
and the security control panel.  
2.2
Specifications
2.2.1 Compatible Control Panels
• DSC PC5010 / Partner P-832 software version v1.XX; v2.X
and higher
• DSC PC1555 / Partner P-6B software version v2.XX and
higher
• DSC PC580 / Partner P-48 software version v2.XX and
higher
• DSC PC5015 / Partner P-832DL software version v1.XX;
v2.2X and higher
• DSC PC5020/PC5020CF / Partner P-8+/P-8+CF software
version v3.2X and higher
2.2.2 Communication Method
• AMPS Control Channel
2.2.3 Dual Path Communications
• The system can be used as the sole method of communica-
tion to the central station or as a second transmission path in
addition to the standard land line.
Please contact your central station on dual signal com-
munication.
• Automation system at central station must be able to sup-
press redundant signals.
2.2.4 Antenna
• 3 dB gain, TNC connector
• Extension Kits available:
LAE - 3: The 3 Foot Antenna Kit for Skyroute Transceiver
LAE - 15: The 15 Foot Antenna Kit for Skyroute Transceiver
LAE - 25: The 25 Foot Antenna Kit for Skyroute Transceiver
SKR - 025: The 25 Foot External Antenna Kit 
2.2.5 RF Power Output
• 
1.2 Watts maximum
2.2.6 Power Supply Ratings
• 12 V
DC
 @30mA, from panel Keybus;  DSC Keybus control
panel required
• 12 V
DC
, from bell circuit
Current in standby 90mA
Current when receiving 135mA
Current when transmitting 1.3A
• For DSC control panels the required minimum transformer is
one rated at 16V
AC
 40 VA. The minimum battery require-
ment is 12V
DC
 7Ah.
2.2.7 Dimension
• 3.5” x 4.6” x 1.8” (85 mm x 115 mm x 45 mm)
2.2.8 Weight
• 0.5 lbs. (0.2 kg)
2.2.9 Operating Temperature
• 0°C - 49°C (32°F - 120°F)
• 85% humidity, non-condensing
*Cellemetry is a registered trademark of Numerex Corporation.