Introduction
Section 1: Introduction
The Skyroute CL3050 is a standalone wireless communicator that sends alarm system infor-
mation to Connect 24. Connect 24 then forwards this information to the central station.
The Skyroute CL3050 has four modes of operation. It can operate in one of three opera-
tional modes or; if it is connected to a keypad, in the programming mode. The Skyroute
CL3050 is pre-programmed with the most commonly used settings for quick installation. If
required the default options can be custom programmed.
NOTE: For UL Installations, use mode 2 or 3 ONLY.
Mode 1: Bell Follower 
In Mode 1, the Skyroute CL3050 monitors the Bell Output of the control panel.
The system identifies the Bell Output cadence and transmits the corresponding
Fire or Burglar alarm reporting code to Connect 24.
Refer to the appropriate control panel Installation Manual.
NOTE: Not for UL Listed installations.
Mode 2: 2-Zone Panel 
In Mode 2, the system will configure itself for 2 zone, stand alone operation.
NOTE: UL Listed for residential burglary installations ONLY.
Mode 3: 8-Zone Panel
If the Skyroute CL3050 detects a PC5108 expander card on power up it will auto-
matically configure itself for 8-zone standalone operation with normally closed
loops.
NOTE: Standalone operation is intended for household fire and burglary and it is
considered ancillary operation for commercial fire and burglary installations.
Programming Mode 
If the Skyroute CL3050 detects a keypad on power up it will go into the program-
ming mode. Programming mode allows the installer to custom program system
options. Refer to Section 5, Programming Descriptions; and Section 6, Program-
ming Worksheets for programming options and default settings.
Figure 1
CL3050