Digital Security Controls Ltd. 05SKYCL User Manual

Page of 28
Skyroute CL3050  Universal Wireless Communicator
3
Section 2: Quick Start
2.1 Installation
1
Determine The Operating mode required
The operating mode (modes 1, 2, or 3) will determine how the unit is to be wired
up. Refer to section 6, Programming Descriptions, section [10] for available
options and for programming defaults. See section 4, Power up Sequence for
selection of Operating and Programming modes.
NOTE: For UL Installations, use only mode 2 or 3.
2
Determine the Mounting Location
Select a mounting location in a dry, protected area. The mounting location
should be positioned so that it is at least 30 cm. away from physical contact with
any person.
NOTE: Do Not exceed the following recommendations for wire run distances
Keybus and zone wiring should be run using minimum 22 gauge quad 
(0.5mm). Two pair twisted is preferred. 
a keypad, PC5108, or zone wiring can not exceed 1,000'/305m (in wire 
length) from the Skyroute CL3050.
Shielded wire is not necessary unless wires are run in an area that may present 
excessive RF noise or interference.
Refer to section 6, Programming Descriptions, section [10] for zone wir-
ing details.
NOTE: Generally, the higher the location and the closer that the Skyroute CL3050
is to an outside wall, the better the signal strength will be.
3
Checking Signal Strength
Remove  front  cover
Connect Battery to the RED and BLK flying leads.
Connect AC Power source or 12 V
DC
 to RED & BLK terminals.
Allow unit to power up
NOTE: The unit does not need to be enrolled with Connect 24 to check signal
strength.
When the green LED stops flashing, press and release the enroll button.
Ensure that Radio Signal Strength Indication (RSSI) is greater than the mini-
mum acceptable level as indicated below. If the signal level is not accept-
able, reposition and retest the Skyroute CL3050 until an acceptable signal 
strength is found.
Red LED
Yellow LED
Green LED
Signal Strength
On
On
On
On
On
Flash
On
On
On
Flash
Off
Off
On
Flash
Off
Off
Off
Off
>87%
69-87%
*52-68%
34-51%
16-33%
0-15%
*Minimum recommended signal strength for enrollment
4
Route Wiring to Mounting Location
Route wiring from the hardwired zones or control panel as required.
NOTE:  Route wiring through conduit to a junction box if possible. Mount the
Skyroute Panel.