Digital Security Controls Ltd. 06PC5132 User Manual

Page of 24
1
This manual describes how to install, program and maintain the RF5132-433.
Before you install the RF5132-433 module, you should complete the following steps
in your system installation:
1. Plan the installation and wiring of the security system (see your system
Installation Manual).
2. Install the control panel, and install and enroll at least one keypad to use for
programming.
3. Install and enroll any hardwired zone expander modules (PC5108) you plan to use.
NOTE: PC5108 zone expander modules occupy zones in 2 groups of 4 (e.g., zones
9-12 and zones 13-16). None of the zones assigned to a PC5108 module can be
used for wireless devices.
Program the RF5132-433 from a system keypad or using downloading software on
a remote computer. Read your system 
Installation Manual for more information.
1.1 How to Use this Manual
Read this manual before you begin installing the RF5132-433. To install and set up the
RF5132-433 and wireless devices, follow these steps. Refer to the sections listed below.
1. Temporarily mount  and wire the RF5132-433 module (see 
Section 2).
2. Enroll and program wireless devices (see 
Section 3).
3. Complete zone and other programming on the system (see 
Section 4).
4. Test the placement of all the wireless devices 
(see Section 5).
5. Permanently mount the RF5132-433 receiver and wireless devices 
(see Section 5).
For additional information on trouble conditions, RF jamming signal detection and
battery replacement, see 
Section 6.
For help with troubleshooting, see 
Section 7.
1.2 Specifications and Features
• Current Draw: 80 mA
• Frequency: 433 MHz
• Zones - receiver can receive signals from up to 32 wireless zones and 16
wireless keys
• Supervisory - programmable supervisory window, 8 to 24 hours, in 15 minute
increments 
(For NA version only)
• Location
- can be wired up to 750 ft. / 230 m from the main panel with 22 gauge wire
- connects to Keybus
- for longer wire runs, thicker gauge wire must be used.
• Compatibility: The RF5132-433 v5.X can be connected to the following
panels:
 
PC501X, PC5020, PC1555, PC580, PC1616, PC1864.
S E C T I O N  1
Introduction