Digital Security Controls Ltd. 06PC5132 User Manual

Page of 24
3
S E C T I O N  2
This section describes how to set up and wire the RF5132-433 module.
2.1 Unpack the RF5132-433
Check that the following parts are in your RF5132-433 package:
• RF5132-433 PCB
• Hardware for mounting the cabinet
• RF5132-433 plastic cabinet
2.2 Choose a Mounting Location for the RF5132-433
NOTE: Mount the RF5132-433 receiver and wireless devices after you have done
placement tests with the wireless devices (see sections 5.1 and 5.2).
Find a place that is:
• Dry
• Central to the proposed placement of all wireless devices
• As high as possible
• Far from sources of interference, including: electrical noise (computers,
televisions and electric motors in appliances and heating and air
conditioning units); large metal objects like heating ducts and plumbing
which may shield the antenna.
Make sure that electrical wires will not run over the module when it is mounted.
When mounting the RF5132-433 in a basement, place the module as high and as
close to the underside of the first floor as possible. The range of the module will be
reduced if the unit is mounted below ground level.
2.3 Connect the RF5132-433 Receiver 
CAUTION: Remove all power from the system while connecting modules to the
Keybus.
Connect the RF5132-433 to the four-wire
Keybus of the control panel according to the
following diagram.
After you have completed the wiring, reconnect
the power to the security system.
Now that you have wired the RF5132-433, you
should enroll and program the wireless de-
vices. See section 3 for instructions.
RF5132-433 Set Up & Wiring