CONNECTING THE GS3060
(1) Ear
(1) Ear
(1) Ear
(1) Ear
(1) Earth Gr
th Gr
th Gr
th Gr
th Ground
ound
ound
ound
ound
This terminal must be connected to the Mains Earth, in order to comply with the Telecommunications
Network Safety Standards (Overvoltage Protection Requirements).
TIP (2) / RNG (3) Exter
TIP (2) / RNG (3) Exter
TIP (2) / RNG (3) Exter
TIP (2) / RNG (3) Exter
TIP (2) / RNG (3) External telephone line
nal telephone line
nal telephone line
nal telephone line
nal telephone line
These terminals must be connected directly to the incoming telephone line .
T1 (4) / R1 (5) Inter
T1 (4) / R1 (5) Inter
T1 (4) / R1 (5) Inter
T1 (4) / R1 (5) Inter
T1 (4) / R1 (5) Internal telephone line
nal telephone line
nal telephone line
nal telephone line
nal telephone line
These terminals must be connected to the TIP and RING of the control panel.
COM(6,14) Common
COM(6,14) Common
COM(6,14) Common
COM(6,14) Common
COM(6,14) Common
This terminal is connected internally to Power Ground.
PGM1 (7), PGM2 (8), PGM3 (9), PGM4 (10) Pr
PGM1 (7), PGM2 (8), PGM3 (9), PGM4 (10) Pr
PGM1 (7), PGM2 (8), PGM3 (9), PGM4 (10) Pr
PGM1 (7), PGM2 (8), PGM3 (9), PGM4 (10) Pr
PGM1 (7), PGM2 (8), PGM3 (9), PGM4 (10) Programmable open-collector outputs
ogrammable open-collector outputs
ogrammable open-collector outputs
ogrammable open-collector outputs
ogrammable open-collector outputs
These outputs can be activated by programmed events, refer to “Activating the Outputs” for details.
The maximum current sink of each output must not exceed 50mA.
AUX+ (11) Auxiliar
AUX+ (11) Auxiliar
AUX+ (11) Auxiliar
AUX+ (11) Auxiliar
AUX+ (11) Auxiliary 12V Output
y 12V Output
y 12V Output
y 12V Output
y 12V Output
+12V Output, 200mA PTC Protected. 
 NOTE: Cur
 NOTE: Cur
 NOTE: Cur
 NOTE: Cur
 NOTE: Currrrrrent drawn fr
ent drawn fr
ent drawn fr
ent drawn fr
ent drawn from this ter
om this ter
om this ter
om this ter
om this terminal is dir
minal is dir
minal is dir
minal is dir
minal is directly fr
ectly fr
ectly fr
ectly fr
ectly from
om
om
om
om
the power supply
the power supply
the power supply
the power supply
the power supply. This needs to be added to the GS3060 cur
. This needs to be added to the GS3060 cur
. This needs to be added to the GS3060 cur
. This needs to be added to the GS3060 cur
. This needs to be added to the GS3060 currrrrrent when deter
ent when deter
ent when deter
ent when deter
ent when determining the total
mining the total
mining the total
mining the total
mining the total
draw on the host panel or power supply
draw on the host panel or power supply
draw on the host panel or power supply
draw on the host panel or power supply
draw on the host panel or power supply. Jumper JP3 does not limit the cur
. Jumper JP3 does not limit the cur
. Jumper JP3 does not limit the cur
. Jumper JP3 does not limit the cur
. Jumper JP3 does not limit the currrrrrent available on
ent available on
ent available on
ent available on
ent available on
this output.
this output.
this output.
this output.
this output.
T
T
T
T
Tamper (12-13)
amper (12-13)
amper (12-13)
amper (12-13)
amper (12-13)
These terminals are connected in series to the Tamper microswitch [11
11
11
11
11]. They will be closed when
the cabinet is properly closed, and will open when the front cover is removed.
Z1-Z4 (15-16-17-18) Pr
Z1-Z4 (15-16-17-18) Pr
Z1-Z4 (15-16-17-18) Pr
Z1-Z4 (15-16-17-18) Pr
Z1-Z4 (15-16-17-18) Programmable Inputs
ogrammable Inputs
ogrammable Inputs
ogrammable Inputs
ogrammable Inputs
These terminals can be set up to trigger events. Refer to “Inputs” section for details.
12V (19), COM (20) Device Power Supply
12V (19), COM (20) Device Power Supply
12V (19), COM (20) Device Power Supply
12V (19), COM (20) Device Power Supply
12V (19), COM (20) Device Power Supply
These terminals must be connected to a rated power supply.
Once the connections are completed, connect the Red and Black wires [13
13
13
13
13] to a 12V, 1.2Ah battery.
Jumper JP3
Jumper JP3
Jumper JP3
Jumper JP3
Jumper JP3
JP3 ON - 
JP3 ON - 
JP3 ON - 
JP3 ON - 
JP3 ON - Full power comes from the host panel or external power supply. Supply must be capable
of up to 700mA, the GS3060 battery must NOT be connected.
JP3 OFF - Cur
JP3 OFF - Cur
JP3 OFF - Cur
JP3 OFF - Cur
JP3 OFF - Currrrrrent Limiting Mode.  
ent Limiting Mode.  
ent Limiting Mode.  
ent Limiting Mode.  
ent Limiting Mode.  Host panel or external supply provide standby current. Supply must
be capable of 120mA plus any current drawn from AUX+ terminal. GS3060 battery must be installed for
proper operation. The Power Supply must have a minimum voltage of 13.5 to ensure sufficient battery
charge.
NOTE: When disposing of batteries, follow the instructions and and precautions printed on
the batteries, and contact your municipal offices for information on the disposal of used
batteries.
STATUS LEDS
The GS3060 interface has 4 status LEDs.
NOTE: The top two LEDs will blink during the Initializing and Programming phases.
The following section describes the Control panel status LEDs.
     RED — This LED is Normally OFF, it will blink in the event of trouble. This LED will switch ON
within 3 minutes in the event of GSM Module [17
17
17
17
17] trouble, or when the GSM Network is unavailable
(NO SERVICE). If this LED blinks, the following list will indicate the specific trouble based on the
number of blinks, by priority.  On power-up, the GS3060 will check for trouble conditions to be
restored in the order listed below. It will indicate the status of the highest priority, unrestored
trouble condition with the corresponding number of flashes of the RED LED.
Once the highest priority trouble condition has been cleared, the next highest priority trouble condition
will be displayed.
1 flash
1 flash
1 flash
1 flash
1 flash - Battery Trouble
(Battery absent or battery with low voltage output)
2 flashes
2 flashes
2 flashes
2 flashes
2 flashes - Radio/SIM Failure 
(Battery absent or check SIM Card connection)
3 flashes
3 flashes
3 flashes
3 flashes
3 flashes - GSM Network Problem 
(SIM not active, poor signal strength, antenna not
connected)