To adjust for ranges between 3m and 18m slide the detection element up or down to 
correspond with the desired distance. Each step between 3m and 18m represents 3m of  
range. 
             Maximum Range (18m, 60ft)  
        Minimum Range (3m, 10ft)  
 
 
 
8.3  Sensitivity, Range and Pet immunity Adjustment  
The calibration of range and sensitivity is performed by a single 16 position rotating switch.
 
There are 3 groups of switch settings grouped according to desired detection range. 
Each group is divided into several levels of sensitivity according to the installation 
environment. 
The sensitivity is determined by a single 16 position rotating switch. Changing the 
sensitivity affects immunity to environmental noises, and also affects the detection distance 
and pet immunity level. 
The rotating switch is marked with digits from “0” to “9” and following letters from “A” to “F”. 
Position “0” is maximum sensitivity and “F” is minimum sensitivity. 
Note: Adjust sensitivity according to environmental conditions! 
Group A - positions 0 – 5 – set sensitivity for 18m detection range with immunity to pets weight 
up to 20kg  
Group B - positions 6 – A – set sensitivity for 13m detection range with immunity to pets weight 
up to 35kg  
Group C - positions B – F – set sensitivity for 7m detection range with immunity to pets weight 
up to 35kg  
NOTE: Ensure that you select the group with a range corresponding to or slightly higher then 
the range set in 8.2. Do not select a group setting that has a lower range then the range set in 
8.2.