Digital Security Controls Ltd. 09WS4913 User Manual

Page of 4
 
                                                        1 
 
WS4913 Series Wireless   
Carbon Monoxide Alarm   
  Installation and Operating Instruction   
       
Read this instruction sheet thoroughly before installation and use of 
the WS4913 wireless carbon monoxide alarm   
Introduction 
The WS4913 is a wireless electrochemical Carbon Monoxide alarm , 
which is effective for detecting any buildup of carbon monoxide , also 
known as CO gas, in your home or office. The features of your CO alarm 
includes: 
(1) Easy to install. 
(2)  Monitoring for carbon monoxide in a continuous manner. 
(3) Giving a loud alarm (85 dB) when it detects a buildup of carbon 
monoxide. 
(4)  Having a Test button for you to test the CO alarm anytime. 
(5) Self-diagnostic testing its operative function continuously. 
(6) Complying the requirements of UL Standard 2034, 2075, UL Canada 
ULC and EU standard EN50291.
 
 
 
 
 
 
 
Operation  
The green LED flashes approx. once in 60 seconds , which means the unit 
is receiving power and also indicates it is sensing carbon monoxide level in 
the air. 
CO alarm   
The CO alarm unit will go into alarm when the CO concentration level 
around the area exceeds the 'alarm' threshold, During an alarm, the red 
LED light flashes rapidly and buzzer sounds with repeating 4 quick beeps 
and pause 5 seconds and then 4 quick beeps.   
Tamper  
The removal of the CO alarm from the mounting plate initiates a 'tamper' 
transmission. The horn chirps once in a minute and the yellow LED is 
steadily on until the unit is mounted back to the plate. 
 
 
Wireless Transmissions 
 
Battery: 
The WS4913 is powered by a 3V DC lithium battery
.
 
 
 
WARNING
:
 Use only battery specified as above mentioned. 
Use of a different battery may have a detrimental effect on alarm 
operation.
 
 
 
Installing/Replacing battery: 
(1) Open the battery cover to expose the battery compartment.. 
(2)  Remove the old battery and properly dispose of them as recommended 
by the battery manufacturer. 
(3)  Note the polarities of the battery are correctly installed as per the 
polarity marking indicated on two sides of the battery cover,make 
sure to carefully seat the red battery warning flag in the recess of the 
battery compartment. 
(4) Gently close the battery cover. The battery cover of CO alarm will not 
close if battery is not properly installed.   
 
 
Caution: 
Constant exposures to high or low temperatures or 
high humidity may reduce battery life.
     
The low battery threshold is set so the battery will provide no less than 30 
days of operation and at that point the CO alarm    will send a 'low battery' 
signal. If the battery is low ,horn will 'chirp' once every 60 seconds with 
yellow LED flash until battery failure. Please replace the battery asap 
before battery power is completely exhausted. 
 
 
 
Caution:  
Constan exposures to high or low temperatures or high humidity may 
reduce battery life.
     
 
The low battery threshold is set so the battery will provide no less than 30 
days of operation and at that point the CO alarm    will send a 'low battery' 
signal. If the battery is low ,horn will 'chirp' once every 60 seconds with 
yellow LED flash until battery failure. Please replace the battery asap 
before battery power is completely exhausted.   
 
Installation Instructions
 
 
 
Locations to install your CO alarm   
Since CO gas moves freely in the air, the suggested location is in or as 
near as possible to sleeping areas of the home. The human body is most 
vulnerable to the effects of CO gas during sleeping hours. For maximum 
protection, a CO alarm should be located outside primary sleeping areas 
or on each level of your home. In the figure 1 below, are suggested 
locations in the home. The electronic sensor detects carbon monoxide, 
measures the concentration and sounds a loud alarm before a potentially 
harmful level is reached.   
 
 
Do not place the CO alarm in the following areas: 
(a)  Where the temperature may drop below 40℉ (4.4℃) or exceed   
100℉ (37.8℃) 
(b)  Near paint thinner fumes 
(c)  Within 5 feet (1.5 meter) of open flame appliances such as furnaces, 
stoves and fireplaces 
(d)  In exhaust streams from gas engines, vents, flues or chimneys 
(e)  Do not place in close proximity to an automobile exhaust pipe; this 
will damage the Alarm
 
 
Installing your CO alarm   
Your WS4913 CO alarm is easy to install to protect you and your family in 
your home, cottage, cabin and office.   
 
To install the CO alarm (See figure 2 as below) :
 
 
1.  At the place where you are going to install the alarm, draw a horizontal 
line six (6) inches long. 
2. Remove the mounting bracket from your unit by rotating it 
counterclockwise. 
3.  Place the bracket so that the two longest hole slots are aligned on the 
line. In each of keyhole slots, draw a mark to locate a mounting plug 
and screw. 
4.  Remove the bracket. 
5. Using a 3/16-inch (5mm) drill bit, drill two holes at the marks and insert 
wall plugs. 
6. Using the two screws and wall plugs (all supplied ), attach the bracket 
to the wall.   
7. Line up the side slot of the bracket and the alarm. Push the alarm onto 
the mounting bracket and turn it clockwise to fix it into place. Pull 
outward on the alarm to make sure it is securely attached to the 
mounting bracket. 
 
 
 
 
 
 
 
 
 
Trouble Singal
Power / Alarm Singal
Test / Reset Button 
Battery Compartment