Digital Security Controls Ltd. 09WS4913 User Manual

Page of 4
 
                                                        3 
however, you have to maintain the CO alarm frequently to ensure it is 
working properly. Few tips are provided for you to take care of your CO 
alarm:  
 
(a)Use a vacuum cleaner to clean the CO alarm cover once a month, 
using the soft brush attachment,    never use water, cleaners as they may 
damage the unit. 
 
(b)Press the Test/silence button to test its operating function once every 
week. 
 
Never disassemble the CO Alarm; there are no user serviceable parts 
inside the unit. You may only remove CO Alarm from backplate to 
replace battery if not serviced by installer. When replacing the battery, 
follow the instructions specified within the Installation Instructions, 
Item 3 Install Batteries..
   
CAUTION: 
This product uses lithium battery, improper handling 
may result in a HEAT, EXPLOSION or FIRE causing personal injury. 
DO NOT recharge batteries.. Follow the battery manufacturer’s safety 
instructions. Dispose of used batteries in accordance with the 
regulations in your area.  
 
Never paint the unit. Paint may prevent CO    from entering the unit. 
If you are planning renovations or repainting, contact your installer 
and ask that the unit be temporarily removed until work is complete.
 
 
 
Specifications 
WS4913 Series Carbon Monoxide Alarm is engineered to be able to 
provide alarm sounds with various exposure time at different level of 
carbon monoxide concentrations as per UL 2034 and EN50291 
standards.  
 
This CO alarm WS4913 meets following mentioned response times : 
At 70ppm , the unit must alarm within 60-240 minutes
 
 
 
At 150ppm, the unit must alarm within 10-50 minutes
 
 
 
At 400ppm, the unit must alarm within 4-15 minutes 
 
 
 
 
 
Product Specifications: 
 
Sensor: Electrochemical carbon monoxide sensor   
Diameter (base) : 12.5cm 
Height(including base): 3.5cm 
Power : 3.6V lithium battery , the battery life lasts around 3 years under 
normal operation condition 
Alarm audibility: Over 85dB at 3m 
Operation Temperature: -10℃ to 40℃ 
Relative Humidity: 10~95%RH 
Low Battery Detection: Low battery 30 days remaining 
Approved Batteries:   
 
 
Alarm indications   
The red ,green, yellow LED light and sound turn on and/or off to indicate 
various situations. There are a few different LED light and sound 
operations.
 
 
Power on mode:
 Three LEDs blink and buzzer beeps for 0.5 second 
as soon as the battery are installed.
 
 
Stand-by mode
green LED flashes once in every 60 seconds, which 
means the unit is receiving power and also indicates it is functioning 
properly.
 
 
 
CO Alarm mode
When the unit sensors CO which is at alarming level , 
the red LED light flashes rapidly and buzzer sounds loudly with repeating 4 
quick beeps and pause 5 seconds and then 4 quick beeps.
 
 
 
Low battery warning mode : 
The yellow LED flashes once in a 
minute and the buzzer chirps also once in a minute. This warning should 
last for up to 30 days , but please replace the battery asap before battery 
power is completely exhausted.
 
 
 
Malfunction (Error) mode
The yellow LED flashes three times in a 
minute and buzzer chirps once in a minute. This indicates the unit is 
malfunctioned and needs to be replaced. 
 
Low sensitivity mode
The yellow LED flashes twice in a minute and 
buzzer chirps once in a minute. This means unit needs to be replaced. 
 
       
 
End of life signal mode
: The yellow LED flashes four times in a minute 
and buzzer chirps once in a minute. This indicate the CO alarm unit is 
reaching the end of this useful life (around 5 years after the unit is 
purchased), please replace with the new CO alarm. 
 
Tamper mode :
 The buzzer chirps once in a minute and the yellow LED 
is steadily on .until the CO alarm unit is mounted back to the bracket 
properly. 
 
 
This manual shall be used in conjunction with the installation 
manual of the alarm control panel . All the instructions specified 
within that manual must be observed. 
 
 
WARNING AND LIMITATION
 
 
 
WARNING!!
 
This product is intended for use in ordinary indoor 
locations of family living units . It is not designed to measure compliance 
with Occupational Safety and Health Administration (OSHA) commercial 
or industrial standards. 
 
Individuals with a medical problem may consider using warning devices 
which provide audible and visual signals for carbon monoxide 
concentrations under 30ppm.
 
 
 
The CO alarm is not suitable as a smoke or fire alarm /detector. This CO 
alarm is not suitable to install in a hazardous location, as defined in the 
National Electrical Code. 
 
 
This CO alarm will not work without power. WS4913 series Carbon 
Monoxide Alarm will not work if the battery power is disconnected or cut 
off for any reason. Additionally, carbon monoxide must reach the CO 
alarm unit for the proper performance of CO gas detection. 
 
 
Carbon monoxide alarms may wear out because they contain electronic 
parts that fail at any time. Test your CO alarm at least every week (see 
the section "TEST AND SILENCE YOUR CO ALARM"). 
 
 
Limited Warranty:   
Digital Security Controls warrants that for a period of twelve months from 
the date of purchase, the product shall be free of defects in materials and 
workmanship under normal use and that in fulfillment of any breach of 
such warranty, Digital Security Controls shall, at its option, repair or 
replace the defective equipment upon return of the equipment to its repair 
depot. This warranty applies only to defects in parts and workmanship 
and not to damage incurred in shipping or handling, or damage due to 
causes beyond the control of Digital Security Controls such as lightning, 
excessive voltage, mechanical shock, water damage, or damage arising 
out of abuse, alteration or improper application of the equipment. 
 
 
 
The foregoing warranty shall apply only to the original buyer, and is and 
shall be in lieu of any and all other warranties, whether expressed or 
implied and of all other obligations or liabilities on the part of Digital 
Security Controls. Digital Security Controls neither assumes responsibility 
nor authorizes any other person purporting to act on its behalf to modify 
or to change this warranty, nor to assume for it any other warranty or 
liability concerning this product. 
 
 
 
In no event shall Digital Security Controls be liable for any direct, indirect 
or consequential damages, loss of anticipated profits, loss of time or any 
other losses incurred by the buyer in connection with the purchase, 
installation or operation or failure of this product.   
 
 
Warning: Digital Security Controls recommends that the entire 
system be completely tested on a regular basis. However, despite 
frequent testing, and due to, but not limited to, criminal tampering or 
electrical disruption, it is possible for this product to fail to perform 
as expected   
 
Important Information: Changes or modifications not expressly 
approved by Digital Security Controls could void the user‘s authority to 
operate this equipment.   
 
FCC Compliance Statement 
CAUTION
Changes or modifications not expressly approved by 
DSC could void your authority to use this equipment. 
 
This equipment generates and uses radio frequency energy and if not 
installed and used properly, in strict accordance with the manufacturer‘s 
instructions, may cause interference to radio and television reception. It 
has been type tested and found to comply with the limits for Class B 
device in accordance with the specifications in Subpart C of Part 15 of 
FCC rules, which are designed to provide reasonable protection against 
such interference in any residential installation. However, there is no 
guarantee that interference will not occur in a particular installation . If this 
equipment does cause interference to television or radio reception, which 
can be determined by turning the equipment off and on, the user 
encouraged to try to correct the interference by one or more of the 
following measures: 
Re-orient the receiving antenna 
 
Relocate the alarm control with respect to the receiver       
 
Move the alarm control away from the receiver 
 
Connect the alarm control into a different outlet so that alarm control 
and receiver are on different circuits. 
 
If necessary, the user should consult the dealer or an experienced 
radio/television technician for additional suggestions. The user may find 
the following booklet prepared by the FCC helpful “How to identify and 
resolve Radio/Television Interference Problems”, this booklet is available 
from the U.S. Government Printing Office, Washington , D.C, 20402, 
Stock#004-000-00345-4.