Terminals description
Terminal
Description
-
Ground: this terminal must be connected to the Mains Earth, in order to comply with the Telecommunications Net-
work Safety Standards (Overvoltage Protection Requirements).
LI
Internal telephone line: these terminals must be connected to the control panel or an alternative communication 
terminal.
LE
External telephone line: these terminals can be connected to the PSTN line.
T1
Default: output, PSTN fault.
Programmable terminals.These terminals can be programmed as follow.
– Open collector outputs: these outputs may be activated either by pro-
grammed events (automatic activation), or by a command sent via SMS, 
or through caller recognition (remote activation); please refer to the 
“Output activation” section for further information. The maximum current 
available at each OC output is 100 mA.
– Input lines: when these inputs receive alarm signals, they can activate 
the SMS and telephone dialer functions.
T2
Default: output, no cellular network.
T3
Default: input, interconnection pres-
ence.
T4
Default: output, tamper.
T5
Default: output, GSM fault.
T6
Default: output, Jamming.
M
Negative: Power supply and shared terminal for the Open Collector outputs.
+V
Power supplied by the control panel, at a level between 10.7 and 27.6V
_; 
make sure that this is protected and operating at a limited current; Limited Power Source (LPS) in
conformity with EN 60950-1:2006 standard. To connect the supply use wires with a maximum 3 m length 
and 0.75 mm² cross-section. For shorter wires use suitable cross-sections.