Digital Security Controls Ltd. 17LE4000 User Manual

Page of 29
4
Section 1: Introduction
The LE4000 is a cellular communicator that sends alarm system information to a Sur-Gard System I-IP, II, III, IV or 5 receiver
through an LTE or 3G wireless network. This cellular communicator can be used with UL/ULC Listed compatible control units, as
indicated in the manufacturer's installation instructions.
The performance of the LE4000 depends greatly on cellular network coverage. Therefore, it should not be mounted without first per-
forming placement tests to determine the best location for reception (minimum of one blue/green LED ON). Optional antenna kits –
LTE-8ANT (8ft/2.4m), LTE-15ANT (15ft/4.6m), LTE-25ANT (25ft/7.6m) and LTE-50ANT (50ft/15.2m) are available.
Note: The LE4000 is designed to work with the Contact ID communication format as described in the SIA DC-05 standard, as well
as the SIA communications format as described in the SIA DC-03 standard. Before completing the field installation of the alarm mon-
itoring system please ensure communication with the supervising central station is successful by sending several events and getting
confirmation that they have been received.
1.1 Features
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
Penta-Band
 LTE; Dual-band UMTS Radio
Advanced
 Carrier Selection
Cellular
 Signal Indicator
LTE
 /3G / Internet communication with Sur-Gard SG-System I-IP / II / III / IV / 5
Compatible
 with 4-digit or 10-digit Contact ID communication format as described in SIA DC-05 Standard and the SIA DC- 
03
 standard for 300 baud. Example of suitable compatible alarm panels:
DSC
 Models HS2128, HS2064, HS2032, HS2016, PC1864, PC1832, PC1616, PC4020.
Panel
 Transmission Monitoring for up to four phone numbers
Simulates
 landline
Switches
 automatically to the LTE or 3G network in the event of landline trouble (e.g., line down)
DLS
 support for status, firmware updates and remote debug enable
Remote
 Firmware Upgrade
Remote
 Diagnostics
Case
 and Wall Tamper
Panel
 Format Detection
Programmable
 Input
Programmable
 Output
1.2 Technical Specifications
The input voltage to the LE4000 can be drawn from the UL/ULC Listed control panel or provided by an external UL/ULC Listed
power supply (with battery back-up) rated for the application (external power-limited source).
Power Supply Rating
Input Voltage Class:
Class 2, power limited
Compatible External Power Adapters (2-prong):
DSC
 ADP1310(W)-NAU (US) / ADP1310(W)-NA (Canada)
NOTE:
 For UL/ULC listed installations, the input rating for the external power 
adapter
 is 120V
AC
/60Hz/0.4A.
Input Voltage (Nominal):
13.8V
DC
required
Input Current:
700mA
LE4000 Installation Manual